ERIE, PA ·
OSHA Inspection: GE TRANSPORTATION
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of GE TRANSPORTATION in 2901 EAST LAKE ROAD BUILDING 7, ERIE, PA 16531 (NAICS 336510). OSHA activity number 334327129.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GE TRANSPORTATION
- Site address
- 2901 EAST LAKE ROAD BUILDING 7
- City
- ERIE
- State
- PA
- ZIP
- 16531
- Mailing
- 2901 EAST LAKE ROAD, ERIE, PA 16531
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336510
- Employees
- 4500
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1910.107 H12
- Issued
- Sep 26, 2012
- Abate by
- Oct 26, 2012
- Penalty
- Initial $3,750 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.107(h)(12): Electrostatic spray area(s) were not provided with automatic sprinkler protection or other approved automatic extinguishing equipment a.) Building 7, Powder Coating Booth - On or about, and dates prior to, August 10, 2012 automatic sprinklers or other approved extinguishing equipment was not installed in the powder coat booth. Company employees conducted powder coating operations in the Company's powder coating booth daily throughout each work shift.
Recent events (2)
- · I (S) $3500
- · Z (S) $3750
1910.107 I08
- Issued
- Sep 26, 2012
- Abate by
- Oct 26, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(i)(8): ): Electrical equipment for electrostatic hand spraying was not so interlocked with the ventilation of the spraying area(s) that the equipment cannot be operated unless the ventilation fan(s) are in operation: a.) Building 7, Powder Coating - Company employee conducted powder coating operations in the Company's powder coating booth throughout each workshift. On or about, and dates prior to, August 10, 2012, electrostatic hand-held spray guns were operable when the ventilation fans were not in operation.
Recent events (2)
- · I (O) $0
- · Z (S) $0
1910.134 I05 III
- Issued
- Sep 26, 2012
- Abate by
- Sep 29, 2012
- Penalty
- Initial $7,000 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.134(i)(5)(iii): The compressor's sorbent bed and filters were not maintained and replaced or refurbished periodically as instructed by the manufacturer: a.) Building 7, Supplied Air System, East side of Powder Coating Booth The catalyst filter installed in a compressor line, used to supply breathing air to supplied air respirators, was not replaced as directed by the manufacturer. The manufacturers instructions stated that the catalyst filter must be changed at least every 12 months. On or about May 17, 2012, the documented date of the last catalyst change was October 2, 2010.
Recent events (2)
- · I (S) $3500
- · Z (S) $7000
1910.134 I05 IV
- Issued
- Sep 26, 2012
- Abate by
- Sep 29, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(i)(5)(iv): The employer did not ensure that compressors used to supply breathing air to respirators had tags containing the most recent change date and the signature of the person authorized by the employer to perform the change: a.) Building 7, Supplied Air System, East side of Powder Coating Booth On or about May 17, 2012, the Final charcoal filter on an air compressor line, which was used to supply air to supplied air respirators, was not tagged with the most recent change date. The date listed on the final filter was September 30, 2011. However, company work orders showed the final filter had been last changed on or about February 27, 2012. a.) Building 7, Supplied Air System, East side of Powder Coating Booth - On or about May 17, 2012, the Final charcoal filter on an air compressor line, which was used to supply air to supplied air respirators, was not tagged with the signature of the person authorized by the employer to change sorbent beds and/or filters. The employer required employees to wear supplied air respirators during powder coating operations.
Recent events (2)
- · I (O) $0
- · Z (S) $0
1910.134 E06 I
- Issued
- Sep 26, 2012
- Abate by
- Oct 1, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(6)(i): The employer did not obtain a written recommendation from a physician or other licensed health care professional regarding the employee's ability to use a respirator: a) Powder Coating- The physician's written opinions, maintained by the employer, did not contain the information required by29 CFR 1910.134. The documents stated only that respirator use was "Approved with no restrictions". The employer required employees to wear supplied air respirators during powder coating operations.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at GE Transportation
View GE Transportation's full OSHA safety record →
More inspections in this industry (NAICS 336510)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 334327129.