OSHA Inspection: ALMIGHTY GUTTERS & CONTRACTING SERVICES, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ALMIGHTY GUTTERS & CONTRACTING SERVICES, LLC in 6008 RICKEY STREET, METAIRIE, LA 70003 (NAICS 238170). OSHA activity number 334333911.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Almighty Gutters & Contracting Services, LLC for free Get an email when a new federal OSHA severe-injury report for Almighty Gutters & Contracting Services, LLC is published. One employer, no account, unsubscribe in one click.
Site address
6008 RICKEY STREET
City
METAIRIE
State
LA
ZIP
70003
Mailing
801 COLONY PLACE, METAIRIE, LA 70003
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
2
Ownership type
A

6 citations on file for this inspection.

1926.403 B02

Serious Gravity 5 2 instances 2 exposed
Issued
Oct 2, 2012
Abate by
Oct 12, 2012
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:    On or about May 09, 2012, the employer failed to ensure that:      a) a household use power strip was used in the manner in which it was intended.   b) a single gang plastic box was used in the manner in which it was intended.     Employees were allow to utilize a power strip which was plugged into the single gang plastic box as a power source for a Mikita circular saw at the residence that was being renovated. The single gang box was connected directly to the power drop down with romex wiring.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2000

1926.404 B01 I

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 2, 2012
Abate by
Oct 12, 2012
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.404(b)(1)(i): General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.    On or about May 9, 2012, the employer failed to ensure that the electrical panel was equipt with ground fault circuit interrupters (GFCI).  Employees were allow to utilize a power strip which was plugged into the single gang plastic box as a power source for a Mikita circular saw at the residence that was being renovated. The single gang box was connected directly to the power drop down with romex wiring.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2800

1926.404 B01 II

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 2, 2012
Abate by
Oct 12, 2012
Penalty
Initial $2,800 · Current $0 Reduced
All 120-volt, single phase, 15- and 20- ampere recepticale outlets on the consturction site, which wre not parat of the permanent wiring of the building or structure and which were in use by employees, did not have, in operating condition, approved Ground Fault Circuit Interrupters (GFCI) for personnel protection.     On or about May 09, 2012, the employer failed to ensure that Ground Fault Circuit Interrupters (GFCI) for personnel protection were provided. Employees were allowed to utilize electrical power from a single gang plastic box. The single gang plastic box did not have a GFCI.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2800

1926.404 B01 III C

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 2, 2012
Abate by
Oct 12, 2012
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1926.404(b)(1)(iii)(C): An assured equipment grounding conductor program was not being utilized, equipment found to be damaged or defective was being used prior to being repaired:    On or about May 09, 2012, the employer failed to ensure that equipment found to be damaged was repaired prior to use. Employees were allowed to utilize an extension cord that was damaged due to overcurrent at the residence that was being renovated.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2000

1926.403 C

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Oct 2, 2012
Abate by
Oct 12, 2012
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.403(c): Interrupting rating. Equipment intended to break current shall have an interrupting rating at system voltage sufficient for the current that must be interrupted.    On or about May 9, 2012, the employer failed to ensure that breakers were used as an interrupting system. Romex wire was spliced directly into the utility drop down. Employees were using the drop down as a power source for electrical equipment.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2800

1926.405 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 2, 2012
Abate by
Oct 12, 2012
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1926.405(b)(1): Conductors entering boxes, cabinets, or fittings. Conductors entering boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. Unused openings in cabinets, boxes, and fittings shall also be effectively closed.    On or about May 09, 2012, the employer failed to ensure that the electric panel was equip with a dead front. Employees were utilizing the electric panel as a power source for electrically powered equipement.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2000