TEMPLE, TX ·
OSHA Inspection: TITAN MACHINE & DESIGN
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TITAN MACHINE & DESIGN in 2507 W. ADAMS AVE, TEMPLE, TX 76504 (NAICS 332710). OSHA activity number 334335916.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TITAN MACHINE & DESIGN
- Site address
- 2507 W. ADAMS AVE
- City
- TEMPLE
- State
- TX
- ZIP
- 76504
- Mailing
- 2507 W. ADAMS AVE, TEMPLE, TX 76504
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.242 B
- Issued
- May 29, 2012
- Abate by
- Jun 12, 2012
- Penalty
- Initial $1,020 · Current $612 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: On or about May 14, 2012, and at times prior thereto, employees in facility used compressed air in excess of 30 psig for cleaning purposes. The high pressure jet of the compressed air can project debris with dangerous force and the high pressures can damage skin, eyes and other body organs. The compressed air is used to clean debris from machined parts and tables. Air pressure from the nozzles was measured to be approximately 45 psi. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that the pressure in the air nozzles is reduced to 30 psig.
Recent events (2)
- · I (S) $612
- · Z (S) $1020
1910.305 G02 III
- Issued
- May 29, 2012
- Abate by
- Jun 12, 2012
- Penalty
- Initial $1,020 · Current $612 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: On or about May 14, 2012, and at times prior there to, an extension cord used to power a portable lamp did not have strain relief for the connection of the flexible cord to the plug. This electrical junction without strain relief exposed employees to arcing effects due to loose electrical connections where cord strain is directly transmitted to the wire. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that strain relief is used on extension cords.
Recent events (2)
- · I (S) $612
- · Z (S) $1020
More inspections in this industry (NAICS 332710)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334335916.