Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,473Inspections Most recent open 2026-07-28 Last loaded 2026-07-31

OSHA Inspection: HIGH VIEW REHABILITATION & LIVING CENTER

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of HIGH VIEW REHABILITATION & LIVING CENTER in 517 RIVERVIEW STREET, MADAWASKA, ME 04756 (NAICS 623110). OSHA activity number 334344520.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch High View Rehabilitation & Living Center — free Get an email when a new federal OSHA severe-injury report for High View Rehabilitation & Living Center is published. One employer, no account, unsubscribe in one click.
Site address
517 RIVERVIEW STREET
City
MADAWASKA
State
ME
ZIP
04756
Mailing
517 RIVERVIEW STREET, MADAWASKA, ME 04756
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
623110
Employees
151
Ownership type
A

4 citations on file for this inspection.

1910.147 C01

Serious Gravity 1 1 instance 6 exposed
Issued
Jun 21, 2012
Abate by
Jun 28, 2012
Penalty
Initial $2,700 · Current $2,160 Reduced
29 CFR 1910.147(c)(1):     Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.    Facility-wide:  The employer did not establish energy control procedures for The elevator, boilers, dryers, hot water heaters and other equipment with multiple sources of energy to ensure that no unexpected startup or release of stored energy could occur.
Recent events (2)
  • — I (S) $2160
  • — Z (S) $2700

1910.132 D02

Other-than-serious 1 instance 151 exposed
Issued
Jun 21, 2012
Abate by
Jun 26, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(2):     The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment.      Facility - The employer did not certify the workplace personal protective hazard assessment as required by this section.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 E01 II

Other-than-serious 1 instance 151 exposed
Issued
Jun 21, 2012
Abate by
Jun 28, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1)(ii):     The methods the employer will use to inform employees of the hazards of non-routine tasks (for example, the cleaning of reactor vessels), and the hazards associated with chemicals contained in unlabeled pipes in their work areas.    Facility - The employer had not developed methods to be used to inform employees of the hazards of non-routine tasks.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 E02

Other-than-serious 1 instance 151 exposed
Issued
Jun 21, 2012
Abate by
Jun 28, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(2):     "Multi-employer workplaces." Employers who produce, use, or store hazardous chemicals at a workplace in such a way that the employees of other employer(s) may be exposed (for example, employees of a construction contractor working on-site) shall additionally ensure that the hazard communication programs developed and implemented under this paragraph (e) include the following: (i) how the employer will proviide on site access to material safety data sheets, (ii) what precautionary measures need to be taken to protect employees, and (iii) the employer's labeling system:    Facility -  the employer had not established a procedure to inform outside contractors about the hazardous chemicals on the worksite.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334344520.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.