Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: B&J GENERAL CONSTRUCTION

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of B&J GENERAL CONSTRUCTION in LEONE POLICE SUBSTATION, PAGO PAGO, AS 96799 (NAICS 236220). OSHA activity number 334351764.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch B&J General Construction — free Get an email when a new federal OSHA severe-injury report for B&J General Construction is published. One employer, no account, unsubscribe in one click.
Site address
LEONE POLICE SUBSTATION
City
PAGO PAGO
State
AS
ZIP
96799
Mailing
P.O. BOX 6623, PAGO PAGO, AS 96799
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
8
Ownership type
A

6 citations on file for this inspection.

1926.303 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 21, 2012
Abate by
Sep 12, 2012
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.303(b)(2): The safety guard did not cover the spindle end, nut, and flange projections:    a) Leone Police Substation, south end:  On or about May 7, 2012 and at times prior thereto, 4 inch BOSCH grinder (1347A) was used without the guard exposing the workers to the rotating, moving parts of the grinder.
Recent events (1)
  • — Z (S) $1200

1926.403 B02

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 21, 2012
Abate by
Sep 12, 2012
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:    a) Leone Police Substation, south end:  On or about May 7, 2012 and at times prior thereto, the junction box outlet connected to extension cord lying on the ground was not approved on construction sites and exposing the workers to electric shock and severe burns.
Recent events (1)
  • — Z (S) $1200

1926.405 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 21, 2012
Abate by
Sep 12, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.405(b)(2): All pull boxes, junction boxes, and fittings were not provided with covers:    a) On or about May 7, 2012 and at times prior thereto, the junction box outlet connected to extension cord lying on the ground was not covered with a cover plate exposing workers to live wires and an electrical shock hazard.
Recent events (1)
  • — Z (S) $0

1926.404 B01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 21, 2012
Abate by
Sep 12, 2012
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites.    a) Leone Police Substation, south end:  On or about May 7, 2012 and at times prior thereto, the electrical extension cord used for portable power tools such as the 4 inch BOSCH  grinder was not equipped or protected by a ground fault circuit interrupter (GFCI) exposing the workers to electric shock and severe burns.
Recent events (1)
  • — Z (S) $1600

1926.404 F01 IV A

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 21, 2012
Abate by
Sep 12, 2012
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.404(f)(1)(iv)(A): AC premises wiring system of 50 volts to 1000 volts was not grounded.     a) Leone Police Substation, east end:  On or about May 7, 2012 and at times prior thereto, main outlet for electrical extension cords was not grounded exposing workers to an electrical shock hazard.
Recent events (1)
  • — Z (S) $2000

1926.404 F06

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 21, 2012
Abate by
Sep 12, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:    a) Leone Police Substation, south end:  On or about May 7, 2012 and at times prior thereto, the electrical extension cord used for the Bosch grinder was not provided with a ground prong, exposing workers to electrical shock hazard.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334351764.