EASTON, PA —
OSHA Inspection: MAGNETIC WINDINGS COMPANY
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of MAGNETIC WINDINGS COMPANY in 2711 FREEMANSBURG AVENUE, EASTON, PA 18042 (NAICS 335314). OSHA activity number 334356714.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAGNETIC WINDINGS COMPANY
- Site address
- 2711 FREEMANSBURG AVENUE
- City
- EASTON
- State
- PA
- ZIP
- 18042
- Mailing
- 2711 FREEMANSBURG AVENUE, EASTON, PA 18042
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335314
- Employees
- 90
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.303 B02
- Issued
- Aug 1, 2012
- Abate by
- Aug 31, 2012
- Penalty
- Initial $2,100 · Current $1,470 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Soldering Area in Department CC7: Eleven energized relocatable power taps were used to provide power to equipment not listed in the UL listing such as soldering pots and soldering irons, on or about May 18, 2012. b) Space Room: Three relocatable power taps were used to provide power to equipment not listed in the UL listing such as soldering pots and soldering irons, on or about May 18, 2012. c) Soldering Area in Department CC7: Four box fans were placed vertically in the ceiling above the soldering area to assist with ventilation and the fans were not approved for industrial use, on or about May 18, 2012. d) Space Room: One box fan was placed vertically in the ceiling to assist with ventilation and the fan was not approved for industrial use, on or about May 18, 2012. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1470
- — Z (S) $2100
1910.305 G01 IV B
- Issued
- Aug 1, 2012
- Penalty
- Initial $2,100 · Current $1,470 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and cables were run through holes in walls, ceilings, or floors: a) Department CC7: Four flexible cords were run through ceiling tiles and against the metal drop ceiling supports, on or about May 18, 2012. No abatement certification or documentation required.
Recent events (2)
- — I (S) $1470
- — Z (S) $2100
1910.305 G02 III
- Issued
- Aug 1, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: a) Department CC7: Four flexible cords were not connected to devices or fittings that provided strain relief, on or about May 18, 2012. No abatement certification or documentation required.
Recent events (1)
- — Z (S) $0
1910.1200 H01
- Issued
- Aug 1, 2012
- Abate by
- Aug 16, 2012
- Penalty
- Initial $2,100 · Current $1,470 Reduced
1591
General-duty citation text
29 CFR 1910.1200(h)(1): The employer did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard the employees had not previously been trained about was introduced into their work area a) Department CC7: Employees using solder bars, solder wire, acetone, epoxy, and flux to assemble power supply components were not provided information on the hazards of the chemicals at the time of their initial assignment, on or about May 31, 2012. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1470
- — Z (S) $2100
1904.4 A02
- Issued
- Aug 1, 2012
- Abate by
- Aug 16, 2012
- Penalty
- Initial $700 · Current $490 Reduced
General-duty citation text
29 CFR 1904.4(a)(2): If one or more of the company's establishments are classified in a non-exempt industry, the employer must keep OSHA injury and illness records for all of such establishments: a) Company-wide: An employee sustained an injury to the right finger on April 12, 2012 which required medical attention and at least one day of restricted duty. The employer did not maintain an OSHA 300 log or equivalent form, on or about May 31, 2012. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $490
- — Z (O) $700
1910.134 C02 I
- Issued
- Aug 1, 2012
- Abate by
- Aug 16, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: a) Department CC7: Employees were provided Moldex N95 respirators to use on a voluntary basis and were not provided Appendix D of the standard, on or about May 31, 2012. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states that employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (O) $0
More inspections at Magnetic Windings Company
View Magnetic Windings Company's full OSHA safety record →
More inspections in this industry (NAICS 335314)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334356714.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.