URBANA, IL ·
OSHA Inspection: FLEX-N-GATE CORPORATION
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FLEX-N-GATE CORPORATION in 601 GUARDIAN DRIVE, URBANA, IL 61802 (NAICS 336370). OSHA activity number 334363314.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FLEX-N-GATE CORPORATION
- Site address
- 601 GUARDIAN DRIVE
- City
- URBANA
- State
- IL
- ZIP
- 61802
- Mailing
- P.O. BOX 877, URBANA, IL 61803
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336370
- Employees
- 358
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.147 C04 II
- Issued
- Oct 30, 2012
- Abate by
- Nov 6, 2012
- Penalty
- Initial $7,000 · Current $4,900 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The enrgy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules and techniques to be utilized for the control of hazardous energy, including, but not limited to Items A - D of this section: Employees working at Weld Cell #8 were exposed to the unexpected energization of the Motoman robot while conducting servicing and maintenance such as cleaning or changing the welding tips. The energy control procedures did not include an adequate specific statement of the intended use of the procedure, specific procedural steps for shutting down and isolating equipment to control hazardous energy, specific procedural steps for the placement and removal of lockout devices or specific requirements for testing the eqipiment to determine the effectiveness of the lockout devices.
Recent events (3)
- · F (S) $4900
- · C (S) $7000
- · Z (S) $7000
1910.147 D03
- Issued
- Oct 30, 2012
- Abate by
- Nov 6, 2012
- Penalty
- Initial $7,000 · Current $4,900 Reduced
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy source: a. Employees working at Weld Cell #8 were exposed to the unexpected energization of the Motoman robot while conducting servicing and maintenance such as cleaning or changing the welding tips and all energy isolating devices that were needed to control the energy to the weld cell were not located so as to isolate the equipment from its energy source. b. Employees working at Weld Cell #14 were exposed to the unexpected energization of the FANUC robot while conducting servicing and maintenance such as cleaning or changing the welding tips and all energy isolating devices that were needed to control the energy to the weld cell were not located so as to isolate the equipment from its energy source.
Recent events (3)
- · F (S) $4900
- · C (S) $7000
- · Z (S) $7000
1910.147 D04 I
- Issued
- Oct 30, 2012
- Abate by
- Nov 6, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a. Employees working at Weld Cell #8 were exposed to the unexpected energization of the Motoman robot while conducting servicing and maintenance such as cleaning or changing the welding tips because the Telemecanique XCS Interlock safety switch had a length of chain between the access gate and the interlock key tongue which allowed the access gate to open without initiating a stop signal. The chain installed on the access door on Weld Cell #8 allowed the gate to have an opening of nine inches without initiating the stop signal. b. Employees working at Weld Cell #14 were exposed to the unexpected energization of the FANUC robot while conducting servicing and maintenance such as cleaning or changing the welding tips because the Telemecanique XCS Interlock safety switch had a length of chain between the access gate and the interlock key tongue which allowed the access gate to open without initiating a stop signal. The chain installed on the access door on Weld Cell #14 allowed the gate to have an opening of 5-1/2 inches without initiating the stop signal.
Recent events (3)
- · F (S) $0
- · C (S) $0
- · Z (S) $0
More inspections at Flex-N-Gate Corporation
View Flex-N-Gate Corporation's full OSHA safety record →
More inspections in this industry (NAICS 336370)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 334363314.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.