LANCASTER, PA ·
OSHA Inspection: HAMILTON PRECISION METALS, INCORPORATED
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of HAMILTON PRECISION METALS, INCORPORATED in 1780 ROHRERSTOWN ROAD, LANCASTER, PA 17601 (NAICS 331491). OSHA activity number 334369113.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HAMILTON PRECISION METALS, INCORPORATED
- Site address
- 1780 ROHRERSTOWN ROAD
- City
- LANCASTER
- State
- PA
- ZIP
- 17601
- Mailing
- 1780 ROHRERSTOWN ROAD, LANCASTER, PA 17601
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331491
- Employees
- 70
- Ownership type
- Private (A)
Citations
14 citations on file for this inspection.
1910.22 A02
- Issued
- Sep 14, 2012
- Abate by
- Oct 14, 2012
- Penalty
- Initial $3,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.22(a)(2): The floors of every workroom were not maintained in a clean condition: (a) Bead Blast Operations - The shot blasting media was on the floor along the back of the Bead Blast machine causing a slip hazard, on or about August 16, 2012. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- · I (O) $1500
- · Z (S) $3000
1910.23 D01 III
- Issued
- Sep 14, 2012
- Penalty
- Initial $3,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.23(d)(1)(iii): Stairway(s) less than 44 inches wide having both sides open, did not have one stair railing on each side: (a) Boxing Area - The set of stairs leading to the Records Room was not equipped with standard stair railings along both of the open sides, on or about May 16, 2012. No abatement certification or documentation required.
Recent events (2)
- · I (O) $1500
- · Z (S) $3000
1910.36 G02
- Issued
- Sep 14, 2012
- Penalty
- Initial $5,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.36(g)(2): The exit access was not at least 28 inches wide at all points: (a) Boxing Area - The aisle leading to the Records Room stair was less than 28 inches wide at several points, on or about May 16, 2012. No abatement certification or documentation required.
Recent events (2)
- · I (S) $0
- · Z (S) $5000
1910.110 F02 I
- Issued
- Sep 14, 2012
- Penalty
- Initial $3,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.110(f)(2)(i): Containers in storage were not located so as to minimize exposure to excessive temperature rise, physical damage, or tampering by unauthorized persons: (a) Outside Propane Tank Storage Area - Propane tanks were not protected from physical damage, on or about May 16, 2012. No abatement certification or documentation required.
Recent events (2)
- · I (S) $1500
- · Z (S) $3000
1910.145 C03
- Issued
- Sep 14, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.145(c)(3): Safety instruction sign(s) were not used where there was a need for general instructions and suggestions relative to safety measure(s): (a) Outside Propane Tank Storage Area - A "No Smoking" sign was not posted where the propane tanks were stored, on or about May 16, 2012. No abatement certification or documentation required.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.132 A
- Issued
- Sep 14, 2012
- Abate by
- Dec 13, 2012
- Penalty
- Initial $5,000 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: (a) Hamilton Precision Metals - Employees who periodically accessed the roof to perform maintenance or inspections were not provided with fall protection, on or about August 16, 2012. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- · I (S) $2500
- · Z (S) $5000
1910.147 C04 II B
- Issued
- Sep 14, 2012
- Abate by
- Nov 13, 2012
- Penalty
- Initial $3,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedure did not clearly and specifically outline specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: (a) Hamilton Precision Metals, Incorporated - The energy control procedures for "12 Mill #1" did not include the hydraulics as an energy source and listed tagout instead of locking out the breaker, on or about May 16, 2012. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- · I (O) $1500
- · Z (S) $3000
1910.147 C05 II
- Issued
- Sep 14, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(5)(ii): Lockout devices and tagout devices were not singularly identified: (a) Hamilton Precision Metals, Incorporated - The lockout devices used for locking out equipment were not singularly identified, on or about May 16, 2012. No abatement certification or documentation required
Recent events (2)
- · I (O) $0
- · Z (S) $0
1910.147 C06 II
- Issued
- Sep 14, 2012
- Abate by
- Oct 14, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: (a) Hamilton Precision Metals, Incorporated - The employer did not certify that annual inspections of their energy control procedures had been performed, on or about August 16, 2012. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.147 D03
- Issued
- Sep 14, 2012
- Abate by
- Nov 13, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): (a) Hamilton Precision Metals, Incorporated - Employees performing bearing changes on the mill machines used the emergency stop button instead of locking out the mill, on or about May 16, 2012. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.213 H01
- Issued
- Sep 14, 2012
- Penalty
- Initial $3,000 · Current $2,775 Reduced
General-duty citation text
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the material: (a) Box Area - The Craftsman 10" Radial Arm Saw did not have the lower blade guarded on the right side, on or about May 16, 2012. No abatement certification or documentation required.
Recent events (2)
- · I (S) $2775
- · Z (S) $3000
1910.215 B09
- Issued
- Sep 14, 2012
- Penalty
- Initial $2,550 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): The guard for an abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel: (a) Maintenance Department - The guard on the Black and Decker bench grinder was not installed properly so that the tongue guard could be adjusted as the wheel's diameter decreased, on or about August 23, 2012. No abatement certification or documentation required.
Recent events (2)
- · I (S) $2000
- · Z (S) $2550
1910.253 B04 III
- Issued
- Sep 14, 2012
- Penalty
- Initial $3,000 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: (a) Receiving Area - Oxygen cylinders were stored with propane and acetylene cylinders, on or about May 16, 2012. No abatement certification or documentation required.
Recent events (2)
- · I (S) $2000
- · Z (S) $3000
1910.1200 F05
- Issued
- Sep 14, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(5): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity and the appropriate hazard warning of the hazardous chemical(s) contained therein: (a) ADS Cleaning Line - The tank containing the diluted "Power Cleaner 320HPM" was not labelled with the identity and the appropriate hazard warning, on or about August 16, 2012. No abatement certification or documentation required.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 331491)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 334369113.