OSHA Inspection: KEENE LAKE MANUFACTURING, INC. DBA GULFBREEZE WOODWORKS

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of KEENE LAKE MANUFACTURING, INC. DBA GULFBREEZE WOODWORKS in 11601 56TH COURT N., CLEARWATER, FL 33760 (NAICS 321918). OSHA activity number 334371317.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Keene Lake Manufacturing, INC. DBA Gulfbreeze Woodworks for free Get an email when a new federal OSHA severe-injury report for Keene Lake Manufacturing, INC. DBA Gulfbreeze Woodworks is published. One employer, no account, unsubscribe in one click.
Site address
11601 56TH COURT N.
City
CLEARWATER
State
FL
ZIP
33760
Mailing
11601 56TH COURT N., CLEARWATER, FL 33760
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321918
Employees
6
Ownership type
Private (A)

7 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 6 exposed
Issued
Aug 30, 2012
Abate by
Oct 5, 2012
Penalty
Initial $2,800 · Current $2,800
OSH ACT of 1970 Section (5)(a)(1):   The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to severe burns from potential dust explosion, deflagration and fire hazards caused by the improper design and maintenance of dust collection systems:  a)  Shop - The dust collection system air flow was not sufficient enough to capture explosive wood dust as evidenced by the large amount of wood dust around woodworking machinery and general areas, on or about May 17, 2012.
Recent events (1)
  • · Z (S) $2800

1910.22 A01

Serious Gravity 10 1 instance 6 exposed
Issued
Aug 30, 2012
Abate by
Sep 12, 2012
Penalty
Initial $2,800 · Current $2,800
29 CFR 1910.22(a)(1):     All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.    a)  Shop - There was combustible wood dust on top of ducts, tables, benches, machines and other elevated surfaces, on or about May 17, 2012.
Recent events (1)
  • · Z (S) $2800

1910.22 A02

Serious Gravity 10 1 instance 6 exposed
Issued
Aug 30, 2012
Abate by
Sep 12, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(2):     The floors of every workroom were not maintained in a clean condition:    a)  Shop - There was combustible wood dust on the floor, on or about May 17, 2012.
Recent events (1)
  • · Z (S) $0

1910.107 B09

Serious Gravity 5 1 instance 6 exposed
Issued
Aug 30, 2012
Abate by
Sep 12, 2012
Penalty
Initial $1,600 · Current $1,600
29 CFR 1910.107(b)(9):     A clear space of not less than 3 feet on all sides was not kept free from storage or combustible construction:      a)  Spray Area - There were combustible wood and boxes stored in the area, on or about May 17, 2012.
Recent events (1)
  • · Z (S) $1600

1910.307 C

Serious Gravity 10 2 instances 6 exposed
Issued
Aug 30, 2012
Abate by
Oct 5, 2012
Penalty
Initial $2,800 · Current $2,800
29 CFR 1910.307(c):     Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location:    a)  Shop - Electrical outlet boxes, motors, snap switches, breaker panels, lights, saws, routers, sanders and other electrical equipment were not intrinsically safe, approved for a Class II, Division I location or safe for a Class I, Division I location, on or about May 17, 2012.       b)  Shop - A Dayton vacuum used was not intrinsically safe, approved for a Class II, Division I location or safe for a Class I, Division I location, on or about May 17, 2012.
Recent events (1)
  • · Z (S) $2800

1910.134 E01

Other-than-serious 1 instance 1 exposed
Issued
Aug 30, 2012
Abate by
Sep 12, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1):     The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:      a)  Spray Area - No medical evaluation was provided, on or about May 17, 2012.
Recent events (1)
  • · Z (O) $0

1910.134 C02 I

Other-than-serious 1 instance 1 exposed
Issued
Aug 30, 2012
Abate by
Sep 26, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(i):     Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:      a)  Spray Area - Appendix D was not provided, on or about May 17, 2012.
Recent events (1)
  • · Z (O) $0

View Keene Lake Manufacturing, INC. DBA Gulfbreeze Woodworks's full OSHA safety record →