Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: POWER CONTRACTING CO.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of POWER CONTRACTING CO. in 915 RIDGE ROAD, CARNEGIE, PA 15106 (NAICS 238210). OSHA activity number 334384112.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Power Contracting CO. for free Get an email when a new federal OSHA severe-injury report for Power Contracting CO. is published. One employer, no account, unsubscribe in one click.
Site address
915 RIDGE ROAD
City
CARNEGIE
State
PA
ZIP
15106
Mailing
61 ARCH STREET, CARNEGIE, PA 15106
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
68
Ownership type
A

2 citations on file for this inspection.

1926.502 B01

Other-than-serious 1 instance 1 exposed
Issued
Jun 26, 2012
Penalty
Initial $2,100 · Current $2,100
29 CFR 1926.502(b)(1): The top edge height of top rails, or equivalent guardrail system members, shall be 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level:    a) Job site, 915 Ridge Road, Pittsburgh, PA: On or about May 3, 2012, during electrical installation activities, the employer did not ensure that appropriate fall protection systems or devices were used where workers were exposed to fall hazards of up to approximately 45 feet in that many of the wire cable guardrail systems that were installed along the stairway system openings and the perimeter of the 3rd floor, were below 39".
Recent events (2)
  • · I (O) $2100
  • · Z (S) $2100

1926.502 B04

Other-than-serious 1 instance 1 exposed
Issued
Jun 26, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.502(b)(4): When the 200 pound (890 N) test load specified in paragraph (b)(3) of this section is applied in a downward direction, the top edge of the guardrail shall not deflect to a height less than 39 inches (1.0 m) above the walking/working level:     a) Job site, 915 Ridge Road, Pittsburgh, PA: On or about May 3, 2012, during electrical installation activities, the employer did not ensure that appropriate fall protection systems or devices were used where workers were exposed to fall hazards of up to approximately 45 feet in that the wire cable guardrail systems that were installed along the stairway system openings and the perimeter of the 3rd floor, deflected below 39" when leaned on/pushed on.