OSHA Inspection: EFCO PRODUCTS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of EFCO PRODUCTS, INC. in 130 SMITH STREET, POUGHKEEPSIE, NY 12601 (NAICS 311999). OSHA activity number 334385739.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Efco Products, INC. — free Get an email when a new federal OSHA severe-injury report for Efco Products, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
EFCO PRODUCTS, INC.
Site address
130 SMITH STREET
City
POUGHKEEPSIE
State
NY
ZIP
12601
Mailing
PO BOX 991, POUGHKEEPSIE, NY 12601
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311999
Employees
70
Ownership type
A

7 citations on file for this inspection.

1910.132 D01

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 5, 2012
Abate by
Oct 29, 2012
Penalty
Initial $4,900 · Current $2,000 Reduced
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):    a)  Flavor Room Storage in Dry Mix - On or about May 21, 2011, an employee was exposed to phosphoric acid (85%) while transferring containers without wearing chemical resistant gloves, goggles, face shield, respirator, or a chemical resistant apron.  Phosphoric acid can cause blindness and causes severe burns on the skin and respiratory tract.
Recent events (3)
  • — F (S) $2000
  • — C (S) $4900
  • — Z (S) $4900

1910.151 C

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 5, 2012
Abate by
Oct 29, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.151(c):  Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:      a)  Flavor Room Storage in Dry Mix - On or about May 21, 2012, employees are exposed to corrosive Phosphoric Acid without access to quick flushing of eyes or body.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.178 L01 I

Serious Gravity 5 1 instance 5 exposed
Issued
Oct 5, 2012
Abate by
Oct 29, 2012
Penalty
Initial $2,800 · Current $1,100 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    a)  Production Facility - On or about May 24, 2012, the employer did not train, certify or evaluate powered industrial truck drivers.
Recent events (3)
  • — F (S) $1100
  • — C (S) $2800
  • — Z (S) $2800

1910.178 L04 III

Serious Gravity 5 1 instance 5 exposed
Issued
Oct 5, 2012
Abate by
Oct 29, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operators performance was not conducted at least once every 3 years.    a)  Production Building - On or about May 24, 2012, an employee was operating a powered industrial truck in the kitchen area.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.134 C

Other-than-serious 1 instance 3 exposed
Issued
Oct 5, 2012
Abate by
Oct 29, 2012
Penalty
Initial $700 · Current $300 Reduced
29 CFR 1910.134(c): The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use:      a)  Production Building - On or about May 31, 2012 employees were required to wear tight fitting air purifying respirators (MSA Comfo Classic) while using cleaning chemicals.
Recent events (3)
  • — F (O) $300
  • — C (O) $700
  • — Z (O) $700

1910.134 E01

Other-than-serious 1 instance 3 exposed
Issued
Oct 5, 2012
Abate by
Oct 29, 2012
Penalty
Initial $700 · Current $300 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:    a)  Production Building - On or about May 31, 2012 employees wore tight fitting air purifying respirators (MSA Comfo Classic) while using cleaning chemicals without having medical evaluation.
Recent events (3)
  • — F (O) $300
  • — C (O) $700
  • — Z (O) $700

1910.134 F

Other-than-serious 1 instance 3 exposed
Issued
Oct 5, 2012
Abate by
Oct 29, 2012
Penalty
Initial $700 · Current $300 Reduced
29 CFR 1910.134(f): The employee was required to use a respirator without being fit tested with the same make, model, style and size of respirator that was to be used:      a)  Production Building - On or about May 31, 2012 employees wore tight fitting air purifying respirators (MSA Comfo Classic) while using cleaning chemicals without having a fit test conducted.
Recent events (3)
  • — F (O) $300
  • — C (O) $700
  • — Z (O) $700