BAYTOWN, TX —
OSHA Inspection: RHODIA INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RHODIA INC. in 3439 PARK ST, BAYTOWN, TX 77520 (NAICS 325188). OSHA activity number 334401338.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RHODIA INC.
- Site address
- 3439 PARK ST
- City
- BAYTOWN
- State
- TX
- ZIP
- 77520
- Mailing
- 3439 PARK ST P.O. BOX 331, BAYTOWN, TX 77520
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325188
- Employees
- 35
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.119 D03 II
- Issued
- Nov 21, 2012
- Abate by
- Dec 27, 2012
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1910.119(d)(3)(ii): The employer did not document that the equipment in the process complied with recognized and generally accepted good engineering practices: The employer does not ensure that equipment in the process complies with recognized and generally accepted good engineering practices. Instance a: This violation occurred in the Sulfuric Acid Regeneration Unit where employees were exposed to inhalation, fire and explosion hazards from potential releases of anhydrous ammonia and/or flammable liquids or gasses without ensuring that the relieving back-pressure of conventional relief device(s) did not exceed 10% of the relief device set pressure in accordance with API 520 for relief device(s) such as, but not limited to: 1. PSV 1170 (Anhydrous Ammonia Storage Tank) 2. PSV 1277 (Ammonia Vaporizer, X-401) 3. PSV 214 (Hydrogen Sulfide Knock Out Pot) Instance b: This violation occurred in the Sulfuric Acid Regeneration Unit where employees were exposed to inhalation, fire and explosion hazards from potential releases of anhydrous ammonia and/or flammable liquids or gasses without ensuring that instrumentation designated to perform safety functions was designed and/or documentation developed for the safety system in accordance with ANSI/ISA-84 (IEC 61511) for safety-instrumented systems and/or interlocks such as, but not limited to: 1. The furnace pressure (PT/PI-232) shown as a safeguard in 2007 Unit PHA and utilized to stop all feeds (including alternative raw material A.R.M.) to the furnace on a condition of high pressure in the furnace. 2. The furnace oxygen content (AT/AI-201A & B) shown as a safeguard in the 2007 Unit PHA and utilized to stop all feeds (including A.R.M) to the furnace on a condition of low oxygen in the furnace. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date the employer must submit documentation showing that it is in compliance with the standard, including describing the steps it is taking to ensure that equipment in the process complies with recognized and generally accepted good engineering practices.
Recent events (3)
- — R (S) $7000
- — C (S) $7000
- — Z (S) $7000
1910.119 E03 V
- Issued
- Nov 21, 2012
- Abate by
- Dec 27, 2012
- Penalty
- Initial $7,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.119(e)(3)(v): The process hazard analysis did not address facility siting: The employer does not ensure that the facility siting analysis associated with the 2007 Baytown Furnace PHA addressed the hazards of the process. The facility siting analysis did not identify, evaluate, and control the hazards of explosion, toxic, and/or flammable vapors entering into the following: a. control room b. the alternative raw material (ARM) unloading shack These violation conditions exposed employees to the hazards associated with explosion, the un-controlled release(s) of hydrogen sulfide, and/or flammable vapors. Pursuant to 29 C.F.R. 1903.19, within (10) calendar days of the abatement date the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to address facility siting.
Recent events (3)
- — R (S) $0
- — C (S) $7000
- — Z (S) $7000
1910.119 E05
- Issued
- Nov 21, 2012
- Abate by
- Dec 27, 2012
- Penalty
- Initial $7,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.119(e)(5): The employer did not assure that PHA recommendations were resolved and documented in a timely manner: The employer does not ensure that the teams recommendations from the 2007 Furnace PHA were resolved in a timely manner and that the resolutions are documented for such action item/recommendations as, but not limited to: a. Consider automating the deluge system in the anhydrous ammonia storage area. b. Consider alarming and interlocking density readings on mass flow meters to detect furnace feed changes Pursuant to 29 CFR 1903.19, within (10) calendar days of the abatement date the employer must submit documentation showing that it is in compliance with the standard, including the description of the steps that it is taking to ensure that PHA recommendations are addressed and resolved in a timely manner and that the resolution(s) are documented and retained for the life of the process.
Recent events (3)
- — R (S) $0
- — C (S) $7000
- — Z (S) $7000
1910.119 J02
- Issued
- Nov 21, 2012
- Abate by
- Dec 27, 2012
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1910.119(j)(2): The employer did not establish or implement written procedures to maintain the on-going integrity of process equipment: The employer does not ensure that procedures are written and implemented to ensure the mechanical integrity of process equipment such as but not limited to the low-pressure alarm on the steam ejector (PAL 216) that is designated as a safeguard in the 2007 Baytown Furnace process hazards analysis (PHA). This condition exposed employees to the hazards associated with uncontrolled releases of liquids/vapor and flammable materials into the atmosphere and/or fire and explosions. Pursuant to 29 C.F.R. 1903.19, within (10) calendar days of the abatement date the employer must submit documentation showing that it is in compliance with the standard, including the description of the steps that it has taken to ensure that written procedures are established or implemented to maintain the on-going integrity of the process.
Recent events (3)
- — R (S) $7000
- — C (S) $7000
- — Z (S) $7000
1910.119 J04 I
- Issued
- Nov 21, 2012
- Abate by
- Dec 27, 2012
- Penalty
- Initial $7,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.119(j)(4)(i): The employer did not inspect and test a safeguard to ensure it functions as intended when it is identified/credited as a safeguard in its PHA as protection against an identified hazard/deviation: The employer does not ensure that safeguards designated in the Baytown Furnace PHA are inspected and tested to ensure operability such as but not limited to PAL 216 (PSL-216) exposing employees to the hazards associated with uncontrolled releases of flammable liquids/vapors. Pursuant to 29 C.F.R. 1903.19, within (10) calendar days of the abatement date the employer must submit documentation showing that it is in compliance with the standard that safeguards identified in PHAs are inspected and tested to ensure operability.
Recent events (3)
- — R (S) $0
- — C (S) $7000
- — Z (S) $7000
1910.119 J04 II
- Issued
- Nov 21, 2012
- Abate by
- Dec 27, 2012
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1910.119(j)(4)(ii): Inspections and testing procedures performed on process equipment to maintain its mechanical integrity, did not follow recognized and generally accepted good engineering practices: The employer does not complete a periodic full functional test of plant safety instrumented systems and interlocks to reveal any undetected faults in accordance with recognized and generally accepted good engineering practices (RAGAGEP) such as ISA84/IEC61511 on process equipment including, but not limited to, the following: a. Furnace Oxygen Analyzer (AT-201) b. Furnace Fire Eyes c. Furnace Pressure (PT-232) These violation instances occurred in the Sulfuric Acid Regeneration unit where employees were exposed to the hazards associated with uncontrolled liquids/vapor releases of flammable materials into the atmosphere and/or fire and explosions. Pursuant to 29 C.F.R. 1903.19, within (10) calendar days of the abatement date the employer must submit documentation showing that it is in compliance with the standard, including the description of the steps that it has taken to ensure that inspections and testing procedures performed on process equipment to maintain its mechanical integrity follow recognized and generally accepted good engineering practices.
Recent events (3)
- — R (S) $7000
- — C (S) $7000
- — Z (S) $7000
1910.119 L01
- Issued
- Nov 21, 2012
- Abate by
- Dec 27, 2012
- Penalty
- Initial $7,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.119(l)(1): The employer did not implement procedures to manage changes to process chemicals, technology, equipment, and procedures, and changes to facilities that affect a covered process: The employer does not implement management of change procedures for relief devices being operated with relieving back pressure greater than 10% of set pressure for the following, but not limited to: a. Relief devices on Ammonia Tank T-451 (PSV-1170); b. Relief device on Ammonia Vaporizer X-401 (PSV-1277), These violation instances occurred in the ammonia system unit exposing employees to the hazards associated with uncontrolled releases of anhydrous ammonia liquid and/or vapors into the atmosphere. Pursuant to 29 C.F.R. 1903.19, within (10) calendar days of the abatement date the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that procedures to manage changes to equipment are implemented.
Recent events (3)
- — R (S) $0
- — C (S) $7000
- — Z (S) $7000
1910.119 O04
- Issued
- Nov 21, 2012
- Abate by
- Dec 27, 2012
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1910.119(o)(4): The employer did not promptly determine and document an appropriate response to each of the findings of the compliance audit, and document that deficiencies have been corrected: The employer does not document deficiencies found in the 2010 Facilitated Self-Assessment (FSA) have been corrected. This includes, but is not limited, to the following audit deficiencies as documented in Rhodia Tracking ID PAT-ECO-BT-12-4: b. Number 3 - Ensure files are complete especially the design basis, standards, and codes used for the ammonia system relief valves. c. Number 5 - Determine and document safety integrity levels for the Ammonia and ARM feed system safety interlocks. d. Number 27 - Determine safety integrity levels and appropriate testing for all safety systems (ammonia and ARM feed systems) These violation instances conditions exposed employees to the hazards associated with uncontrolled ammonia and ARM vapor releases into the atmosphere. Pursuant to 29 CFR 1903.19, within (10) calendar days of the abatement date the employer must submit documentation showing that it is in compliance with the standard, including the description of the steps that it is taking to ensure that it promptly determines and documents an appropriate response to each of the findings of the compliance audit, and document that deficiencies have been corrected.
Recent events (3)
- — R (S) $7000
- — C (S) $7000
- — Z (S) $7000
More inspections at Rhodia INC.
View Rhodia INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325188)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334401338.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.