OSHA Inspection: DUCT DESIGN CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DUCT DESIGN CORPORATION in 7850 WEST 22TH AVE, HIALEAH, FL 33016 (NAICS 238990). OSHA activity number 334403748.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Duct Design Corporation — free Get an email when a new federal OSHA severe-injury report for Duct Design Corporation is published. One employer, no account, unsubscribe in one click.
Site address
7850 WEST 22TH AVE
City
HIALEAH
State
FL
ZIP
33016
Mailing
7850 WEST 22TH AVE, HIALEAH, FL 33016
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
38
Ownership type
A

9 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 8, 2012
Abate by
Jun 19, 2012
Penalty
Initial $3,500 · Current $1,900 Reduced
OSH ACT of 1970 Section (5)(a)(1):  The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fall hazards:    (a)  On or about 5/16/2012, at the duct cutting and forming department, Duct Design Corporation, Hialeah, FL.  Employees were exposed to a caught by hazard while working with a hydraulic press brake (Model 10) without point of operation guarding and/or alternate measures which provide effective protection.    Note:  Certification of abatement must be submitted for this citation item.
Recent events (2)
  • — I (S) $1900
  • — Z (S) $3500

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 8, 2012
Penalty
Initial $3,500 · Current $1,900 Reduced
29 CFR 1910.212(a)(1):  Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by: rotating parts:    (a)  On or about 5/16/2012, at the duct assembly department, Duct Design Corporation, Hialeah, FL.  An employee was exposed to a caught by hazard while working with a drill press (Northern Industrial, Model 17209) that lacked a guard on its point of operation.
Recent events (2)
  • — I (S) $1900
  • — Z (S) $3500

1910.212 B

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 8, 2012
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.212(b):  Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:    (a)  On or about 5/16/2012, at the duct assembly department, Duct Design Corporation, Hialeah, FL.  An employee was exposed to a struck by hazard while working with a drill press (Northern Industrial, Model 17209) that was not anchored to the floor.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.215 A04

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 8, 2012
Penalty
Initial $2,800 · Current $1,250 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:    (a)  On or about 5/16/2012, at the spiral department, Duct Design Corporation, Hialeah, FL.  An employee was exposed to a struck by hazard while working with a bench grinder (Ryobi, Model BGH6110) that lacked workrests.
Recent events (2)
  • — I (S) $1250
  • — Z (S) $2800

1910.215 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 8, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9):  The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:      (a)  On or about 5/16/2012, at the spiral department, Duct Design Corporation, Hialeah, FL.  An employee was exposed to a struck by hazard while working with a bench grinder (Ryobi, Model BGH6110) that lacked tongue guards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.304 G05

Serious Gravity 5 3 instances 3 exposed
Issued
Jun 8, 2012
Penalty
Initial $2,800 · Current $1,250 Reduced
29 CFR 1910.304(g)(5):   The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:    On or about 5/16/2012, Duct Design Corporation, Hialeah, FL.    (a)  At the duct cutting and forming department, employees were exposed to an electrical hazard while working in close proximity to an electrical fan (Emerson, Model K55HXLW0-3929) that lacked a ground prong on its attachment plug.      (b)  At the duct assembly department, employees were exposed to an electrical hazard while working in close proximity to an electrical fan (Model HVP-30E) that lacked a ground prong on its attachment plug.     (c)  At the duct assembly department, an employee was exposed to an electrical hazard while working with a drill press (Northern Industrial, Model 17209) that lacked a ground prong on its attachment plug.
Recent events (2)
  • — I (S) $1250
  • — Z (S) $2800

1910.101 B

Other-than-serious 1 instance 7 exposed
Issued
Jun 8, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:     (a)  On or about 5/16/2012, at duct assembly department, Duct Design Corporation, Hialeah, FL.  Four argon cylinders were not secured, exposing employees to a struck by hazard in the event that these were knocked over.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 7 exposed
Issued
Jun 8, 2012
Abate by
Jun 19, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1):  The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    (a)  On or about 5/16/2012, at the spiral area, Duct Design Corporation, Hialeah, FL.  The employer had not developed and implemented a written hazard communication program for protecting employees from chemical hazards presented by hazardous materials (i.e. argon, oxygen, propane, castrol superedge 6724, etc.) they were exposed to on a daily basis.      Note:  Certification of abatement must be submitted for this citation item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 G08

Other-than-serious 1 instance 7 exposed
Issued
Jun 8, 2012
Abate by
Jun 11, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(8):  The employer did not maintain copies of the required material safety data sheets for each hazardous chemical in the workplace:    (a)  On or about 5/16/2012, at Duct Design Corporation, Hialeah, FL.  Materials safety data sheets for hazardous materials that employees were exposed to on a daily basis  (i.e. argon, oxygen, propane, castrol superedge 6724, etc.) were not available, exposing employees to chemical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Duct Design Corporation's full OSHA safety record →