BAYONNE, NJ ·
OSHA Inspection: MAREK'S & SON CONSTRUCTION, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MAREK'S & SON CONSTRUCTION, LLC in 127 24TH ST., BAYONNE, NJ 07002 (NAICS 238170). OSHA activity number 334415148.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAREK'S & SON CONSTRUCTION, LLC
- Site address
- 127 24TH ST.
- City
- BAYONNE
- State
- NJ
- ZIP
- 07002
- Mailing
- 39 W. 31ST ST., BAYONNE, NJ 07002
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 3
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1926.501 B01
- Issued
- Jun 5, 2012
- Penalty
- Initial $2,200 · Current $1,210 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. 127 24th St., Bayonne, NJ:Employees engaged in siding activities without any type of fall protection were exposed to falls of approximately 15 feet to the ground below. Violation observed on or about 5/12/12.
Recent events (2)
- · I (S) $1210
- · Z (S) $2200
1926.1053 B01
- Issued
- Jun 5, 2012
- Penalty
- Initial $1,320 · Current $726 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladders length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigied support that will not deflect, and/or a grasping device was not provided to assist emmployees in mounting and dismounting the ladder. 127 24th St., Bayonne, NJ:Employee's engaged in siding activities were provided with a portable ladder that was not extended 3 feet above the roof edge for safe access. Violation observed on or about 5/12/12.