Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: T.C.DUNHAM PAINT CO.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of T.C.DUNHAM PAINT CO. in 581 SAW MILL RIVER RD., YONKERS, NY 10701 (NAICS 325510). OSHA activity number 334432762.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch T.C.Dunham Paint CO. for free Get an email when a new federal OSHA severe-injury report for T.C.Dunham Paint CO. is published. One employer, no account, unsubscribe in one click.
Site address
581 SAW MILL RIVER RD.
City
YONKERS
State
NY
ZIP
10701
Mailing
581 SAW MILL RIVER RD., YONKERS, NY 10701
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325510
Employees
20
Ownership type
Private (A)

7 citations on file for this inspection.

1910.23 E01

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Oct 23, 2012
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1910.23(e)(1):     The railing did not consist of top rail, intermediate rail, and posts, and did not have a vertical height of 42 inches nominal from upper surface of top rail to floor, platform, runway, or ramp level:    Location: Production Building     a) The top rail missing on railing guarding a work platform located about 7.5 feet above the ground.  Employee climbs onto this work platform to check on the resin level in a storage tank; on or about May 23, 2012.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2000

1910.106 E06 I

Deleted Serious Gravity 5 1 instance 20 exposed
Issued
Oct 23, 2012
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1910.106(e)(6)(i):     Adequate precautions were not taken to prevent the ignition of flammable vapors:    Location: Warehouse    a) An automobile (i.e., source of ignition) was parked in the warehouse where flammable liquids such as but not limited to oil base paints and thinners were stored; on or about May 23, 2012.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2000

1910.120 P01

Deleted Serious Gravity 1 1 instance 10 exposed
Issued
Oct 23, 2012
Abate by
Nov 23, 2012
Penalty
Initial $1,200 · Current $0 Reduced
29 CFR 1910.120(p)(1):     Employers conducting operations at treatment, storage, and disposal (TSD) facilities specified in 29 CFR 1910.120(a)(1)(iv) and who are not exempted by 29 CFR 1910.120(a)(2)(iii) did not develop and/or implement a written safety and health program for employees involved in hazardous waste operations:    Location: 581 Saw Mill River Road     Damaged fifty-five gallon drums containing hazardous chemicals were stored at the facility and the employer had not developed a safety and health program required for treatment, storage, and disposal (TSD) facilities; on or about May 23, 2012.
Recent events (2)
  • · I (S) $0
  • · Z (S) $1200

1910.176 B

Serious Gravity 5 1 instance 10 exposed
Issued
Oct 23, 2012
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1910.176(b):     Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse:    Location: Yard  a) Fifty-five gallon drums stored on wooden pallets were not stable and secure from collapse; on or about May 23, 2012.
Recent events (2)
  • · I (S) $1500
  • · Z (S) $2000

1910.178 F02

Serious Gravity 5 1 instance 20 exposed
Issued
Oct 23, 2012
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1910.178(f)(2):The storage and handling of liquefied petroleum gas fuel was not in accordance with NFPA Storage and Handling of Liquefied Petroleum Gases (NFPA No. 58-1969), which is incorporated by reference as specified in Sec. 1910.6.    a) Employer stored LP Gas tanks in a trailer that did not conform to NFPA 58-1969 Section 5-2.1.1 in that the cylinders in storage were not located to minimize exposure to excessive temperature rise, physical damage, or tampering: on or about May 23, 2012    b) The trailer in which the cylinders were stored did not meet the requirements set forth in Section 5-3.3.3 of NFPA 58-1969 in that adequate vents to the outside were not provided at both top and bottom; on or about May 23, 2012.
Recent events (2)
  • · I (S) $1500
  • · Z (S) $2000

1910.1200 F05 I

Other-than-serious 3 instances 20 exposed
Issued
Oct 23, 2012
Abate by
Nov 22, 2012
Penalty
Initial $1,200 · Current $0 Reduced
29 CFR 1910.1200(f)(5)(i):     The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein:      a) Location: Production Building  Vats containing paint products were not marked with the identity of the hazardous chemical contained therein; on or about May 23, 2012.    b) Location: Yard  Fifty-five gallon drums were not marked with the identity of the hazardous chemical contained therein; on or about May 23, 2012.    c) Location: Elevated working platform in the Production Building  White storage carboys were not marked with the identity of the hazardous chemical contained therein; on or about May 23, 2012.
Recent events (2)
  • · I (O) $0
  • · Z (S) $1200

1910.1200 F09

Other-than-serious 1 instance 3 exposed
Issued
Oct 23, 2012
Abate by
Nov 22, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(9):     The employer did not ensure that labels or other forms of warning were legible, in English, and prominently displayed on the container, or readily available in the work area throughout each work shift:    Location: Yard    a) Labels on fifty-five gallon drums were not maintained in a legible condition so as to identify of the hazardous chemicals contained therein. These fifty-five drums contained hazardous chemicals such as but not limited to ethyl acetate, lacquer, sealer, and VMP  Naptha; on or about May 23, 2012.
Recent events (2)
  • · I (O) $0
  • · Z (S) $0

View T.C.Dunham Paint CO.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 334432762.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.