On , OSHA opened a planned safety inspection of BRATEK ENGINEERING & MANUFACTURING in 2020 S. OSAGE ST., DENVER, CO 80223 (NAICS 332710). OSHA activity number 334432770.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bratek Engineering & Manufacturing for free Get an email when a new federal OSHA severe-injury report for Bratek Engineering & Manufacturing is published. One employer, no account, unsubscribe in one click.
Site address
2020 S. OSAGE ST.
City
DENVER
State
CO
ZIP
80223
Mailing
2020 S. OSAGE ST., DENVER, CO 80223
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
16
Ownership type
A

6 citations on file for this inspection.

1910.101 B

Serious Gravity 1 1 instance 5 exposed
Issued
Nov 7, 2012
Abate by
Nov 18, 2012
Penalty
Initial $1,020 · Current $612 Reduced
29 CFR 1910.101(b): Section 3.3.1, Compressed Gas Association Pamphlet P1 1965, as adopted by 29 CFR 1910.101(b): Compressed gas cylinder(s) ahould be stored in accordance with all local, state and municipal regulations and in accordance with appropriate standards of the Compressed Gas Association and the National Fire Protection Association.     (a)  Bratek Engineering & Manufacturing at 2020 S. Osage St., Denver, CO 80223: On and before 5/21/12, the employer stored oxygen compressed gas cylinders and acetylene cylinders together in the welding shop. Section 3.5.3 of Pamphlet P-1 provides that stored oxygen and fuel gas cylinders should be separated by a minimum of 20 feet, or there should be a fire resistant partition between the oxygen and fuel gas cylinders.       Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (S) $612
  • · Z (S) $1020

1910.212 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 7, 2012
Abate by
Nov 28, 2012
Penalty
Initial $1,700 · Current $1,020 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazards created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:      (a)	Bratek Engineering & Manufacturing at 2020 S. Osage St., Denver, CO 80223: On and before 5/21/12, the employer did not protect employees from hazards created by operating an Amada Shearer single press that was unguarded. A portion of the guard was missing. This condition exposed employees to amputation and crush hazards.      (b)	Bratek Engineering & Manufacturing at 2020 S. Osage St., Denver, CO 80223: On and before 5/21/12, the employer did not protect employees from hazards created by operating an unguarded portion of blade of a horizontal band saw. This condition exposed employees to amputation hazards.      Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (S) $1020
  • · Z (S) $1700

1910.243 C

Deleted Serious Gravity 1 1 instance 4 exposed
Issued
Nov 7, 2012
Abate by
Nov 28, 2012
Penalty
Initial $1,020 · Current $0 Reduced
29 CFR 1910.243(c): All portable, power-driven circular saws having a blade diameter greater than 2 in. shall be equipped with guards above and below the base plate or shoe. The upper guard shall cover the saw to the depth of the teeth, except for the minimum arc required to permit the base to be tilted for bevel cuts. The lower guard shall cover the saw to the depth of the teeth, except for the minimum arc required to allow proper retraction and contact with the work. When the tool is withdrawn from the work, the lower guard shall automatically and instantly return to covering position:      (a)	Bratek Engineering & Manufacturing at 2020 S. Osage St., Denver, CO 80223: On and before 5/21/12, the employer did not protect employees from hazards created by operating a portable hand grinder that was unguarded. This condition exposed employees to eye injuries associated with sparks and flying chips.       Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (S) $0
  • · Z (S) $1020

1910.95 G01

Other-than-serious 1 instance 2 exposed
Issued
Nov 7, 2012
Abate by
Nov 18, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.95(g)(1):     The employer shall establish and maintain an audiometric testing program as provided in this paragraph by making audiometric testing available to all employees whose exposures equal or exceed an 8-hour time-weighted average of 85 decibels:    (a) 	Bratek Engineering & Manufacturing at 2020 S. Osage St., Denver, CO 80223: On and before 5/21/12, the employer did not establish and maintain an audiometric tresting program. This condition exposed employees to excessive noise exposure.      Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.95 G05 I

Other-than-serious 1 instance 2 exposed
Issued
Nov 7, 2012
Abate by
Nov 18, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.95(g)(5)(i): Within 6 months of an employee's first exposure at or above the action level, the employer shall establish a valid baseline audiogram against which subsequent audiograms can be compared.      (a) 	Bratek Engineering & Manufacturing at 2020 S. Osage St., Denver, CO 80223: On and before 5/21/12, the employer did not establish a baseline audiogram within 6 months of an employee's first exposure at or above the action level. This condition exposed employees to excessive noise exposure and hearing loss.      Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.1200 F05 I

Other-than-serious 1 instance 5 exposed
Issued
Nov 7, 2012
Abate by
Nov 18, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein:    (a) 	Bratek Engineering & Manufacturing at 2020 S. Osage St., Denver, CO 80223: On and before 5/21/12, the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemicals contained within.  Simple Green all-purpose cleaning solution was transferred into smaller containers.  This condition exposed employees to a chemical hazard.       Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334432770.