Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: RENE V LOPEZ

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RENE V LOPEZ in 925 MONROE ST, OSHKOSH, WI 54901 (NAICS 238160). OSHA activity number 334435567.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rene V Lopez for free Get an email when a new federal OSHA severe-injury report for Rene V Lopez is published. One employer, no account, unsubscribe in one click.
Establishment
RENE V LOPEZ
Site address
925 MONROE ST
City
OSHKOSH
State
WI
ZIP
54901
Mailing
1125 W MAIN ST, LITTLE CHUTE, WI 54911
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
Private (A)

5 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 2 instances 3 exposed
Issued
Aug 16, 2012
Abate by
Sep 28, 2012
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.501(b)(13):     Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system:      a)  Employees were working on a main roof with a 12:12 pitch and eave edge greater than thirteen (13) feet above compacted surface    b)  Employees were working on a dormer roof with a steep pitch and eave edge greater than nineteen (19) feet above compacted surface    Abatement Certification and Abatement Documentation required
Recent events (3)
  • · F (S) $1000
  • · C (S) $2000
  • · Z (S) $2000

1926.503 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 16, 2012
Abate by
Sep 28, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.503(b)(1):     The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer.      Employer did not provide a written certification of employee fall protection safety training for three employees who did not recognize the fall from elevation hazard when working at a height greater than thirteen (13) feet without utilizing fall protection equipment.      Abatement Certification and Abatement Documentation required
Recent events (3)
  • · F (S) $0
  • · C (S) $0
  • · Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 16, 2012
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.1053(b)(1):     Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:      Employees were utilizing a Bauer Corp twenty-four (24) foot extension ladder to access a roof surface without side rails extending at least three (3) feet above the upper landing surface.      No Abatement Certification and Abatement Documentation required
Recent events (3)
  • · F (S) $1000
  • · C (S) $2000
  • · Z (S) $2000

1926.1053 B09

Serious Gravity 1 2 instances 3 exposed
Issued
Aug 16, 2012
Penalty
Initial $1,200 · Current $600 Reduced
29 CFR 1926.1053(b)(9):     The area around the top and/or bottom of (a) ladder(s) was not kept clear:      a)  Employees were utilizing a Bauer Corp twenty-four (24) foot extension ladder (yellow in color) to access and egress a roof surface with debris under and around the base of the ladder.    b)  Employees were utilizing a twenty-eight (28) foot extension ladder (orange in color) to access and egress a roof surface with debris under and around the base of the ladder.      No Abatement Certification and Abatement Documentation required
Recent events (3)
  • · F (S) $600
  • · C (S) $1200
  • · Z (S) $1200

1926.1060 A01 III

Other-than-serious 1 instance 3 exposed
Issued
Aug 16, 2012
Abate by
Sep 28, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.1060(a)(1)(iii):     The employer did not ensure that each employee using ladders and/or stairways had been trained by a competent person in the proper construction, use, placement, and care in handling the ladders and/or stairways:      Employer did not provide ladder safety training to employees who did not recognize the hazard associated with not extending roof access ladder side rails at least three feet above the upper landing surface and the tripping hazard associated with utilizing roof access/egress extension ladders with debris under and around the base of the ladders.      Abatement Certification and Abatement Documentation required
Recent events (3)
  • · F (O) $0
  • · C (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 334435567.