Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: DAVID SCRIPTURE

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DAVID SCRIPTURE in 2 WHITTEN NECK RD., WOLFEBORO, NH 03894 (NAICS 238160). OSHA activity number 334436136.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch David Scripture for free Get an email when a new federal OSHA severe-injury report for David Scripture is published. One employer, no account, unsubscribe in one click.
Establishment
DAVID SCRIPTURE
Site address
2 WHITTEN NECK RD.
City
WOLFEBORO
State
NH
ZIP
03894
Mailing
205 WATER VILLAGE RD., OSSIPEE, NH 03864
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
Private (A)

6 citations on file for this inspection.

1926.300 B01

Other-than-serious 1 instance 2 exposed
Issued
Jul 13, 2012
Abate by
Jul 16, 2012
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use:    a. Site- Employees were exposed to amputation hazards when a Ryobi table saw was being operated with the guard removed.
Recent events (2)
  • · I (O) $0
  • · Z (S) $2800

1926.501 B13

Other-than-serious 1 instance 1 exposed
Issued
Jul 13, 2012
Abate by
Jul 16, 2012
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.501(b)(13): Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph (b)    a. Site- Employees were not protected from falls of approximately 9 feet 5 inches when fall protection was not used or provided.
Recent events (2)
  • · I (O) $0
  • · Z (S) $2800

1926.503 A02

Other-than-serious 1 instance 1 exposed
Issued
Jul 13, 2012
Abate by
Aug 3, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(2): The employer did not assure that each employee exposed to fall hazards was trained by a competent person qualified in the areas specified in 29 CFR 1926.503 (a)(2)(i) through (viii).    a.Site- Employees were not protected from falls of approximately 9 feet 5 inches when fall protection training was not provided by the employer.
Recent events (2)
  • · I (O) $0
  • · Z (S) $0

1926.1053 B01

Other-than-serious 1 instance 1 exposed
Issued
Jul 13, 2012
Abate by
Jul 16, 2012
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladders length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    a. Site- Employees were not protected from falls of approximately 9 feet 5 inches when a ladder used for access to the roof did not extend 3 feet above the upper landing surface.
Recent events (2)
  • · I (O) $0
  • · Z (S) $2000

1926.403 B02

Other-than-serious 1 instance 2 exposed
Issued
Jul 13, 2012
Abate by
Jul 16, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:    a. Site- employees using a 6 outlet wall tap, which was plugged into a GFCI protected electrical outlet, was not done in accordance with its equipments listing and labeling requirements where it was meant for indoor use only.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1926.405 G02 IV

Other-than-serious 1 instance 2 exposed
Issued
Jul 13, 2012
Abate by
Jul 16, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:    a. Site- employees were allowed to use a damaged cord, which was plugged into a GFCI protected outlet that lacked adequate strain relief.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 334436136.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.