Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EXTREME AUTO BODY & COLLISION, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of EXTREME AUTO BODY & COLLISION, LLC in 5 SHALVOYS LANE, DANBURY, CT 06810 (NAICS 811121). OSHA activity number 334437332.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Extreme Auto Body & Collision, LLC — free Get an email when a new federal OSHA severe-injury report for Extreme Auto Body & Collision, LLC is published. One employer, no account, unsubscribe in one click.
Site address
5 SHALVOYS LANE
City
DANBURY
State
CT
ZIP
06810
Mailing
5 SHALVOYS LANE, DANBURY, CT 06811
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811121
Employees
5
Ownership type
A

11 citations on file for this inspection.

1910.107 E01

Serious Gravity 5 18 instances 4 exposed
Issued
Sep 13, 2012
Abate by
Nov 27, 2012
Penalty
Initial $2,400 · Current $1,200 Reduced
29 CFR 1910.107(e)(1): The storage of flammable or combustible liquids in connection with spraying operations shall conform to the requirements of 1910.106, where applicable.    Workplace: Combustible and Flammable paints, thinners and other chemicals used in the automotive spray painting process were stored on the floor and on work tables. Theses chemicals include but were not limited to:  3M Bondo body filler, Klean Strip Gun cleaner and Bulldog Adhesive Promotor, Trans Star 2K Acrylic Urethane primer and Urethane Reducer Medium, Naked Gun Gold Gun Cleaner, Motor City  Clear Coat 8041, Nason Ful-thane catalyst, 483-15 Ful-Thane Catalyst and 2K 400-1 urethane, TCI DT-5 Virgin Lacquer Thinner,  HB Body 740 Acryl and 722 Hardener, USC 1240-1 Wax, Grease & Silicone Remover, Catalizador E-224 Acrylic Hardener, Mipa 2K Acrylic Clearcoat.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2400

1910.107 B05 I

Serious Gravity 5 2 instances 1 exposed
Issued
Sep 13, 2012
Abate by
Nov 27, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.107(b)(5)(i): The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.    SPRAYBOOTH: The air velocity across the filter on either side of the spray booth while the employee was engaged in spray painting operations was between 69 and 81 feet per minute on the left side and between 73 and 88 feet per minute on the right side of the spray booth.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 C01

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 13, 2012
Abate by
Nov 27, 2012
Penalty
Initial $2,400 · Current $1,200 Reduced
29 CFR 1910.134(c)(1): In any workplace where respirators are necessary to protect the health of the employee or whenever respirators are required by the employer, the employer shall establish and implement a written respiratory protection program with worksite-specific procedures. The program shall be updated as necessary to reflect those changes in workplace conditions that affect respirator use. The employer shall include in the program the following provisions of this section, as applicable:    WORKPLACE: The Employer did not establish and implement a written respiratory protection program where employees were wearing tight fitting, filtering face piece respirators while performing tasks, such as (but not limited to) spray painting, cutting and grinding.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2400

1910.134 E01

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 13, 2012
Abate by
Nov 27, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1):  The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.    WORKPLACE: The employees who were wearing tight fitting half face respirators did not have a medical evaluation conducted to ensure the employees were able to wear the respirators.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F02

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 13, 2012
Abate by
Nov 27, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2):  The employer shall ensure that an employee using a tight-fitting facepiece respirator is fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter.    WORKPLACE: The employees wearing tight fitting half face respirators during the course of work had not received fit testing for each type respirator they were using.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 G01 I A

Serious Gravity 5 4 instances 4 exposed
Issued
Sep 13, 2012
Abate by
Nov 27, 2012
Penalty
Initial $2,400 · Current $1,200 Reduced
29 CFR 1910.134(g)(1)(i)(A): The employer shall not permit respirators with tight-fitting facepieces to be worn by employees who have facial hair that comes between the sealing surface of the facepiece and the face or that interferes with valve function; or any condition that interferes with the face-to-facepiece seal or valve function.    WORKPLACE: The employees were allowed to wear tight fitting half face respirators with facial hair that interfered with the proper sealing of the respirator.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2400

1910.134 H02 I

Serious Gravity 5 4 instances 4 exposed
Issued
Sep 13, 2012
Abate by
Nov 27, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.134(h)(2)(i): All respirators shall be stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals, and they shall be packed or stored to prevent deformation of the facepiece and exhalation valve.    WORKPLACE: Two (2) Gerson model 8200 tight fitting half face respirators were found unprotected and lying on the mixing table and on the paint mixing rack.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 K01 VII

Serious Gravity 5 4 exposed
Issued
Sep 13, 2012
Abate by
Nov 27, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(1): The employer shall ensure that each employee can demonstrate knowledge of at least the following: Why the respirator is necessary and how improper fit, usage, or maintenance can compromise the protective effect of the respirator; What the limitations and capabilities of the respirator are;  How to use the respirator effectively in emergency situations, including situations in which the respirator malfunctions; How to inspect, put on and remove, use, and check the seals of the respirator;What the procedures are for maintenance and storage of the respirator; How to recognize medical signs and symptoms that may limit or prevent the effective use of respirators; and The general requirements of this section.      WORKPLACE: The employees required to wear tight fitting and filtering facepiece face respirators during the course of work were not provided with training.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 5 15 instances 4 exposed
Issued
Sep 13, 2012
Abate by
Nov 27, 2012
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:    WORKPLACE: The employer did not develop and implement a Hazard Communication program, where employees used and were exposed to chemicals such as (but not limited to) 3M Bondo body filler, Klean Strip Gun cleaner, Trans Star 2K Acrylic Urethane primer and Urethane Reducer Medium, numerous Spies Hecker Permacron paints, Naked Gun Gold Gun Cleaner, Motor City  Clear Coat 8041, and Nason Ful-thane catalyst and 2K urethane.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.1200 G01

Serious Gravity 5 10 instances 4 exposed
Issued
Sep 13, 2012
Abate by
Nov 27, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1): Chemical manufacturers and importers shall obtain or develop a safety data sheet for each hazardous chemical they produce or import. Employers shall have a safety data sheet in the workplace for each hazardous chemical which they use.    WORKPLACE: The employer did not have a material safety data sheet for each chemical used in the workplace which includes  (but is not limited to) 3M Bondo body filler, Klean Strip Gun cleaner, Trans Star 2K Acrylic Urethane primer and Urethane Reducer Medium, Naked Gun Gold Gun Cleaner, Motor City  Clear Coat 8041, and Nason Ful-thane catalyst and 2K urethane.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 13, 2012
Abate by
Nov 27, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h): Employees were not provided effective information and training as specified in 29 CFR 1910.1200(h)(1) and -2 on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard was introduced in the workplace.    WORKPLACE: The employer did not provide  training to employees using and exposed to chemicals used in the workplace which includes (but is not limited to) 3M Bondo body filler, Klean Strip Gun cleaner, Trans Star 2K Acrylic Urethane primer and Urethane Reducer Medium, Naked Gun Gold Gun Cleaner, Motor City  Clear Coat 8041, and Nason Ful-thane catalyst and 2K urethane.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334437332.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.