Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: ACROPOLIS ROOFING SYSTEMS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ACROPOLIS ROOFING SYSTEMS in 5507 HOMESTEAD RD., ARLINGTON, TX 76017 (NAICS 238160). OSHA activity number 334437746.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Acropolis Roofing Systems for free Get an email when a new federal OSHA severe-injury report for Acropolis Roofing Systems is published. One employer, no account, unsubscribe in one click.
Site address
5507 HOMESTEAD RD.
City
ARLINGTON
State
TX
ZIP
76017
Mailing
1311 N. RUSK, WEATHERFORD, TX 76086
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
Private (A)

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
May 31, 2012
Abate by
Jun 1, 2012
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1926.501(b)(13):     Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502.      (a)  On or about May 22, 2012, on the left side of the duplex, employees who were removing old roofing materials in preparation for installing a new roof were not using any type of fall protection.  The employees were exposed to falls of approximately 8 feet to the ground below.
Recent events (2)
  • · I (S) $1680
  • · Z (S) $2800

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
May 31, 2012
Abate by
Jun 1, 2012
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1926.1053(b)(1):     Where portable ladders were used for access to an upper landing surface and the ladder length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed.      (a) On or about May 22, 2012, on the left side of the duplex, employees were using an aluminum extension ladder with side rails that did not extend at least 3 feet above the edge of the roof to access the roof.  The employees were exposed to fall hazards of approximately 8 feet to the concrete below.
Recent events (2)
  • · I (S) $960
  • · Z (S) $1600

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 334437746.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.