HOUSTON, TX ·
OSHA Inspection: WESTHEIMER TERRACE APARTMENT MANAGEMENT, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WESTHEIMER TERRACE APARTMENT MANAGEMENT, LLC in 9515 WESTHEIMER ROAD, HOUSTON, TX 77063 (NAICS 238310). OSHA activity number 334439767.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WESTHEIMER TERRACE APARTMENT MANAGEMENT, LLC
- Site address
- 9515 WESTHEIMER ROAD
- City
- HOUSTON
- State
- TX
- ZIP
- 77063
- Mailing
- 9407 WESTHEIMER ROAD, HOUSTON, TX 77063
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 10
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.100 A
- Issued
- Aug 21, 2012
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, were not protected by protective helmets. Building 34C; employees performed carpentry work from a tubular welded frame scaffold without proper head protection, exposing employees to struck-by hazards.
Recent events (2)
- · I (S) $960
- · Z (S) $1600
1926.451 B01
- Issued
- Aug 21, 2012
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows: Building 34C; employees performed carpentry work from a tubular welded frame scaffold platforms that were not fully planked, exposing employees to fall hazards at approximately 19feet.
Recent events (2)
- · I (S) $1200
- · Z (S) $2000
1926.451 E01
- Issued
- Aug 21, 2012
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface were not used. Crossbraces shall not be used as a means of access. Building 34C; employees climbed down the ends of a tubular welded frame scaffold frame to exit the scaffold, exposing employees to fall hazards at approximately 19 feet.
Recent events (2)
- · I (S) $1200
- · Z (S) $2000
1926.451 G01
- Issued
- Aug 21, 2012
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. Note to paragraph (g)(1): The fall protection requirements for employees installing suspension scaffold support systems on floors, roofs, and other elevated surfaces are set forth in subpart M of this part. Building 34C; employees performed carpentry work from a tubular welded frame scaffold platforms that did not have guard rails, exposing employees to fall hazards at approximately 19 feet.
Recent events (2)
- · I (S) $1200
- · Z (S) $2000
1926.452 C02
- Issued
- Aug 21, 2012
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.452(c)(2): Frames and panels shall be braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally. The cross braces shall be of such length as will automatically square and align vertical members so that the erected scaffold is always plumb, level, and square. All brace connections were not secured. Building 34C; employees performed carpentry work from a tubular welded frame scaffold platforms that did not have crossbracing, exposing employees to fall hazards at approximately 19 feet, 9 inches.
Recent events (2)
- · I (S) $1200
- · Z (S) $2000
More inspections at Westheimer Terrace Apartment Management, LLC
View Westheimer Terrace Apartment Management, LLC's full OSHA safety record →