Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TK CONSTRUCTION & MASONRY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TK CONSTRUCTION & MASONRY, INC. in 4655 N. HERMITAGE AVE., CHICAGO, IL 60640 (NAICS 238140). OSHA activity number 334441334.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch TK Construction & Masonry, INC. — free Get an email when a new federal OSHA severe-injury report for TK Construction & Masonry, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4655 N. HERMITAGE AVE.
City
CHICAGO
State
IL
ZIP
60640
Mailing
5816 W. IRVING PARK RD. APT. 2, CHICAGO, IL 60634
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
2
Ownership type
A

6 citations on file for this inspection.

1926.451 D03 VI

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 15, 2012
Penalty
Initial $2,000 · Current $800 Reduced
29 CFR 1926.451(d)(3)(vi): Outrigger beams that were not stabilized by bolts or other direct connections to the floor or roof deck were not secured by tiebacks:    a) The outrigger beams supporting the two-point adjustable suspension scaffold did not have any direct connection to the roof and were not tied back.    No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $800
  • — Z (S) $2000

1926.451 D16

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 15, 2012
Penalty
Initial $2,000 · Current $800 Reduced
29 CFR 1926.451(d)(16): The suspension scaffold power-operated hoist or manually operated hoist did not have, in addition to the normal operating brake, a braking device or locking pawl which engages automatically when a hoist makes either of the following uncontrolled movements: an instantaneous change in momentum or an accelerated speed.    a)  Employees were working from a two-point adjustable suspension scaffold which did not have a breaking device or locking pawl.     No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $800
  • — Z (S) $2000

1926.451 D17

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 15, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(d)(17):  Manually operated hoists did not have a positive crank force to descend:    a)  Employees were working from a two-point adjustable suspension scaffold where the manually operated hoist did not have a positive crank force to descend.    No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G03 I

Serious Gravity 5 2 instances 1 exposed
Issued
Jun 15, 2012
Abate by
Jun 18, 2012
Penalty
Initial $2,000 · Current $800 Reduced
29 CFR 1926.451(g)(3)(i): Vertical lifelines were not fastened to a fixed safe point of anchorage, independent of the scaffold, and protected from sharp edges and abrasion:    a) Vertical lifelines used by employees were not secured to a safe point of anchorage.      b) Vertical lifelines were not protected from abrasion.      In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $800
  • — Z (S) $2000

1926.451 G04 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 15, 2012
Abate by
Jun 18, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(4)(iv): Midrails were not installed at a height approximately midway between the top edge of the guardrail system and the platform surface:    a) No midrail was present on the scaffold.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 15, 2012
Abate by
Jun 18, 2012
Penalty
Initial $2,000 · Current $800 Reduced
29 CFR 1926.501(b)(4)(i):  Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels by personal fall arrest systems, covers or guardrail systems erected around such holes:    a)  Employees were not protected from the hazard of falling approximately 10 feet to the lower level while working around an unguarded skylight.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $800
  • — Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334441334.