Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TILEY ROOFING, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of TILEY ROOFING, INC. in 1112 N. SPEER BLVD., DENVER, CO 80204 (NAICS 238160). OSHA activity number 334443744.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tiley Roofing, INC. — free Get an email when a new federal OSHA severe-injury report for Tiley Roofing, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
TILEY ROOFING, INC.
Site address
1112 N. SPEER BLVD.
City
DENVER
State
CO
ZIP
80204
Mailing
5399 FEDERAL BLVD., DENVER, CO 80221
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.501 B10

Other-than-serious 3 exposed
Issued
Jun 14, 2012
Abate by
Jul 4, 2012
Penalty
Initial $2,142 · Current $1,285 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, warning line system and personal fall arrest system, or warning line system and safety monitoring system; or, on roofs 50 feet (15.25 m) or less in width, the use of a safety monitoring system alone:    (a) Tiley Roofing, Inc., @ 1112 N. Speer Blvd., Denver, CO 80204: On and before 5/24/12, employees engaged in roofing activities on a flat, commercial roof which measured less than 50ft in its least dimension were not protected from a fall hazard. This condition exposed employees to a fall hazard of approximately 15.4ft as measured from ground to eve.
Recent events (2)
  • — I (O) $1285
  • — Z (S) $2142

1926.502 H01 V

Other-than-serious 3 exposed
Issued
Jun 14, 2012
Abate by
Jul 4, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.502(h)(1)(v): The safety monitor had other responsibilities which took the monitors attention from the monitoring function:     (a) Tiley Roofing, Inc., @ 1112 N. Speer Blvd., Denver, CO 80204: On and before 5/24/12, the safety monitor assisted in roofing activities while outside the warning line system on a flat, commercial roof. Additionally, the safety monitor failed to monitor employees while they conducted roofing activities outside the warning line system. This condition exposed employees to a fall hazard of approximately 15.4ft as measured from ground to eve.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

View Tiley Roofing, INC.'s full OSHA safety record →