MANSFIELD, TX ·
OSHA Inspection: APOLINAR HIDALGO
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of APOLINAR HIDALGO in 1301 GENESIS DR., MANSFIELD, TX 76063 (NAICS 238350). OSHA activity number 334448933.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- APOLINAR HIDALGO
- Site address
- 1301 GENESIS DR.
- City
- MANSFIELD
- State
- TX
- ZIP
- 76063
- Mailing
- 3121 PARK ROW DR. APT 267, ARLINGTON, TX 76010
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238350
- Employees
- 7
- Ownership type
- A
Citations
9 citations on file for this inspection.
1926.25 A
- Issued
- Sep 24, 2012
- Abate by
- Sep 27, 2012
- Penalty
- Initial $1,200 · Current $662 Reduced
General-duty citation text
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, form or scrap lumber with protruding nails was not kept clear from work areas: (a) On or about May 24, 2012, at the front of the house, scrap lumber and other debris were not kept clear from the work areas or in and around the house during the construction of this residence, exposing employees to the hazards of lacerations and/or puncture injuries caused by stepping on nails.
Recent events (2)
- · I (S) $662
- · Z (S) $1200
1926.403 B02
- Issued
- Sep 24, 2012
- Abate by
- Sep 27, 2012
- Penalty
- Initial $2,800 · Current $1,558 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: (a) On or about May 24, 2012, inside the house, an outlet box was used to connect several power tools to the electrical source and was not used in accordance with manufacturer's instructions and specifications. Employees who used the tools that were plugged into this box were exposed to the hazard of electrical shock or electrocution.
Recent events (2)
- · I (S) $1558
- · Z (S) $2800
1926.404 F06
- Issued
- Sep 24, 2012
- Abate by
- Sep 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, and enclosures was not permanent and continuous. (a) On or about 5/24/12, inside the house, the plug on the cord for the Makita circular saw did not have a ground prong. The employees using this saw were exposed to the hazard of electrocution.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.416 E01
- Issued
- Sep 24, 2012
- Abate by
- Sep 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: (a) On or about 5/24/12, inside the house, the extension cord that was being used to power the Makita circular saw was damaged and the damage was covered by using black electrical tape. The employees using this saw were exposed to the hazard of electrical shock.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.451 A06
- Issued
- Sep 24, 2012
- Abate by
- Sep 27, 2012
- Penalty
- Initial $2,000 · Current $1,120 Reduced
General-duty citation text
29 CFR 1926.451(a)(6): Scaffolds were not designed by a qualified person: (a) On or about 5/24/12, at the front of the house, the scaffold that was being used to perform cornice work had not been designed by a qualified person. The employee using this scaffold was exposed to fall hazards of approximately 16 feet to the ground below.
Recent events (2)
- · I (S) $1120
- · Z (S) $2000
1926.451 B02
- Issued
- Sep 24, 2012
- Abate by
- Sep 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: (a) On or about 5/24/12, on the front of the house, an employee was standing on a plank that was approximately 12 inches wide while performing cornice work. The employee was exposed to falls of approximately 16 feet to the ground below.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.451 E01
- Issued
- Sep 24, 2012
- Abate by
- Sep 27, 2012
- Penalty
- Initial $2,000 · Current $1,120 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. (a) On or about 5/24/12, at the front of the house, a ladder was not provided for accessing the scaffold. The employee climbed through a window to access the scaffold and was exposed to fall hazards of approximately 16 feet to the ground below.
Recent events (2)
- · I (S) $1120
- · Z (S) $2000
1926.451 G01 VII
- Issued
- Sep 24, 2012
- Abate by
- Sep 27, 2012
- Penalty
- Initial $2,000 · Current $1,120 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. (a) On or about 5/24/12, at the front of the house, an employee was performing cornice work from a scaffold without being protected from falling to the ground below by having any type of fall protection. The employee was exposed to fall hazards of approximately 16 feet to the ground below.
Recent events (2)
- · I (S) $1120
- · Z (S) $2000
1926.1052 C01 II
- Issued
- Sep 24, 2012
- Abate by
- Sep 27, 2012
- Penalty
- Initial $1,200 · Current $10 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge. (a) Inside the house, the stairway which had 8 risers that had no stairrail system along the unprotected side, was used by the employees to access the second floor of the house. These employees were exposed to falls of up to approximately 48 to 64 inches to the concrete floor below.
Recent events (2)
- · I (S) $10
- · Z (S) $1200