COOPER CITY, FL —
OSHA Inspection: SUPREME CEILING & INTERIORS, INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SUPREME CEILING & INTERIORS, INC in 8900 STIRLING ROAD, COOPER CITY, FL 33024 (NAICS 236220). OSHA activity number 334473139.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SUPREME CEILING & INTERIORS, INC
- Site address
- 8900 STIRLING ROAD
- City
- COOPER CITY
- State
- FL
- ZIP
- 33024
- Mailing
- 5941 NW 176TH STREET UNIT #4, HIALEAH, FL 33015
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 15
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 B01
- Issued
- Aug 28, 2012
- Penalty
- Initial $1,360 · Current $816 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): On or about 5/17/12, workers were working on a scaffold approximately 10' above ground level where the working levels of the scaffold were not fully planked.
Recent events (2)
- — I (S) $816
- — Z (S) $1360
1926.451 E01
- Issued
- Aug 28, 2012
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: On or about 5/17/12, workers were working on a scaffold approximately 10' above ground level that did not have a means of egress to and from the scaffold.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1926.451 G01 VII
- Issued
- Aug 28, 2012
- Penalty
- Initial $1,360 · Current $816 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: On or about, 5/17/12, workers were working on a two tier scaffold approximately 10' above the ground level, whereas the scaffold was not erected with guardrails.
Recent events (2)
- — I (S) $816
- — Z (S) $1360
More inspections at Supreme Ceiling & Interiors, INC