Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: DAVE'S UPHOLSTERY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DAVE'S UPHOLSTERY in 1143 S. CLEVELAND MASSILLON RD., COPLEY, OH 44321 (NAICS 811420). OSHA activity number 334476736.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dave'S Upholstery for free Get an email when a new federal OSHA severe-injury report for Dave'S Upholstery is published. One employer, no account, unsubscribe in one click.
Establishment
DAVE'S UPHOLSTERY
Site address
1143 S. CLEVELAND MASSILLON RD.
City
COPLEY
State
OH
ZIP
44321
Mailing
1143 S. CLEVELAND MASSILLON RD., COPLEY, OH 44321
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811420
Employees
5
Ownership type
Private (A)

14 citations on file for this inspection.

1910.22 A01

Serious Gravity 1 1 instance 4 exposed
Issued
Oct 24, 2012
Abate by
Nov 23, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition:    On 5/29/2012, the first and second floors of the building were overly cluttered with upholstery materials, equipment and supplies including ceiling tiles that were damaged and severely water stained and missing, plastic material hanging below the ceiling in the office area to catch the rain water leaks, and landscaping timbers used as vertical structural supports for the office and showroom roof.
Recent events (1)
  • · Z (S) $0

1910.24 I

Serious Gravity 1 1 instance 4 exposed
Issued
Oct 24, 2012
Abate by
Nov 23, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.24(i): Vertical clearance above any stair tread to an overhead obstruction was not at least 7 feet measured from the leading edge of the tread:    On and before 5/29/2012, the fixed staircase leading to the second floor had a wooden horizontal beam that was 5 feet 1 inch above the leading edge of a stair tread.
Recent events (1)
  • · Z (S) $0

1910.37 A03

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 24, 2012
Abate by
Nov 8, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:    On 5/29/2012, the exit route and discharge on the second floor was blocked by upholstery material and the outside exit staircase was missing from the building.
Recent events (1)
  • · Z (S) $0

1910.141 B01 I

Serious Gravity 1 1 instance 4 exposed
Issued
Oct 24, 2012
Abate by
Nov 8, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.141(b)(1)(i): Potable water was not provided in all places of employment, for drinking, washing of the person, cooking, washing of foods, washing of cooking or eating utensils, washing of food preparation or processing premises, and personal service rooms:    On 5/29/2012, the workplace did not have potable drinking water available for the employees.
Recent events (1)
  • · Z (S) $0

1910.141 D02 II

Serious Gravity 1 1 instance 4 exposed
Issued
Oct 24, 2012
Abate by
Nov 8, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.141(d)(2)(ii): Lavatories were not provided with hot and cold, or tepid running water:    On 5/29/2012, the hot water tank in the restroom was not working.
Recent events (1)
  • · Z (S) $0

1910.157 C04

Serious Gravity 1 1 instance 4 exposed
Issued
Oct 24, 2012
Abate by
Oct 29, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition:    On 5/29/2012, the portable fire extinguisher on the first floor at the restroom was not fully charged and operable.
Recent events (1)
  • · Z (S) $0

1910.157 E02

Serious Gravity 1 2 instances 4 exposed
Issued
Oct 24, 2012
Abate by
Oct 29, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:    On and before 5/29/2012, portable fire extinguishers had not received the monthly inspection.
Recent events (1)
  • · Z (S) $0

1910.157 G01

Serious Gravity 1 1 instance 4 exposed
Issued
Oct 24, 2012
Abate by
Nov 23, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting:    On and before 5/29/2012, the employer did not provide portable fire extinguisher training.
Recent events (1)
  • · Z (S) $0

1910.219 D01

Serious Gravity 1 2 instances 2 exposed
Issued
Oct 24, 2012
Abate by
Nov 8, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    On 5/29/2012, the Consew and Juki industrial sewing machines on the second floor had rotating pulley drives that were not guarded at the ingoing nip points.
Recent events (1)
  • · Z (S) $0

1910.242 B

Serious Gravity 1 1 instance 2 exposed
Issued
Oct 24, 2012
Abate by
Nov 8, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    On 5/29/2012, the compressed airline used for cleaning at the sewing machine area on the second floor was at 75 psi.
Recent events (1)
  • · Z (S) $0

1910.303 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Oct 24, 2012
Abate by
Oct 29, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    On 5/29/2012, the second floor sewing room had a non-industrial grade electrical multiple tap switch being used to provide power to equipment such as but not limited to the window air conditioner.
Recent events (1)
  • · Z (S) $0

1910.304 B02 III

Serious Gravity 1 1 instance 2 exposed
Issued
Oct 24, 2012
Abate by
Oct 29, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.304(b)(2)(iii): The grounding contacts of receptacles and cord connectors were not grounded by connection to the equipment grounding conductor of the circuit supplying the receptacle or cord connector:    On 5/29/2012, the Consew sewing machine had a flexible cord plug that was connected to an extension cord without a ground receptacle which allowed the ground prong to be exposed.
Recent events (1)
  • · Z (S) $0

1910.1200 E01

Serious Gravity 5 1 instance 4 exposed
Issued
Oct 24, 2012
Abate by
Nov 23, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    On and before 5/29/2012, the employer did not have a hazard communication program for chemicals such as but not limited to spray adhesives, spray paints and furniture stain.
Recent events (1)
  • · Z (S) $0

1910.141 A05

Other-than-serious 1 instance 4 exposed
Issued
Oct 24, 2012
Abate by
Nov 8, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.141(a)(5): Enclosed workplaces were not so constructed, equipped, and maintained as to prevent the entrance or harborage of rodents, insects, or other vermin:    On and before 5/29/2012, there were non-domestic cats inhabiting the second floor amid the upholstery material and in the recent past they have had litters.
Recent events (1)
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 334476736.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.