TAMPA, FL —
OSHA Inspection: VINCENT CORPORATION
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of VINCENT CORPORATION in 2810 5TH AVE, TAMPA, FL 33605 (NAICS 333294). OSHA activity number 334477536.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VINCENT CORPORATION
- Site address
- 2810 5TH AVE
- City
- TAMPA
- State
- FL
- ZIP
- 33605
- Mailing
- 2810 5TH AVE, TAMPA, FL 33605
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333294
- Employees
- 30
- Ownership type
- A
Citations
13 citations on file for this inspection.
1910.147 C04 II
- Issued
- Sep 19, 2012
- Abate by
- Nov 1, 2012
- Penalty
- Initial $2,800 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D) a) Plant - Maintenance Department The lockout/tagout program did not list specific procedural steps for the shutting down, isolating, blocking, and the securing of specific machines and equipment such as but not limited to cranes, lathes, press brake, shear, etc; in order to control hazardous energy, on or about, 08/03/12.
Recent events (2)
- — I (S) $2000
- — Z (S) $2800
1910.178 L04 III
- Issued
- Sep 19, 2012
- Abate by
- Nov 1, 2012
- Penalty
- Initial $2,100 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operators performance was not conducted at least once every 3 years a) Plant - Forklifts operators were not evaluated following their initial training on 04/16/09, on or about, 08/03/12.
Recent events (2)
- — I (S) $1500
- — Z (S) $2100
1910.178 Q07
- Issued
- Sep 19, 2012
- Abate by
- Sep 28, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(q)(7): Forklift examinations were not made at least daily. a) Plant - Yale LPG Forklift - Serial# E187V12288X Forklifts were not inspected on a daily basis as required by the standard, on or about, 08/03/12.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 P01
- Issued
- Sep 19, 2012
- Abate by
- Nov 1, 2012
- Penalty
- Initial $2,800 · Current $500 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Where powered industrial trucks were found to be in need of repair, defective, or in any way unsafe, the trucks were not taken out of service until they had been restored to safe operating condition a) Plant - Yale LPG Forklift - Serial # E187V12288X The forklift was not removed from servicce despite the presence of badly worn rear tires and defective lights, on or about, 05/11/12.
Recent events (2)
- — I (O) $500
- — Z (S) $2800
1910.179 B05
- Issued
- Sep 19, 2012
- Abate by
- Sep 19, 2012
- Penalty
- Initial $2,800 · Current $500 Reduced
General-duty citation text
29 CFR 1910.179(b)(5): The rated load of crane(s) was not plainly marked on each side of the crane: a) Throughout Plant - Jib Cranes N1, N7, S-1, S-2 & W-2/Overhead Cranes 2&5 Ton Rated load markings were not provided on both sides of the Jib cranes, and the load ratings on the overhead cranes were not legible from the workfloor, on or about, 05/11/12.
Recent events (2)
- — I (O) $500
- — Z (S) $2800
1910.179 J02 III
- Issued
- Sep 19, 2012
- Abate by
- Nov 1, 2012
- Penalty
- Initial $2,800 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.179(j)(2)(iii): A certification record which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the hook inspected, was not maintained: a) Plant - Overhead & Gantry Cranes Monthly inspections of the crane's hoist hooks with a certification record which included the date of the inspection, signature of the inspector, and the serial number or other identifier of the hook inspected was not performed, on or about, 05/11/12.
Recent events (2)
- — I (S) $2000
- — Z (S) $2800
1910.179 J02 IV
- Issued
- Sep 19, 2012
- Abate by
- Nov 1, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(j)(2)(iv): Monthly inspections of hoist chains, with a certification record which includes the date of inspection, the signature of the person who performed the inspection and an identifier of the chain which was inspected, were not performed: a) Plant - Overhead & Gantry Cranes Monthly inspections of hoist chains with a certificate record which includes the date of the inspection, the signature of the inspector, and an identifier of the chain were not performed, on or about, 05/11/12.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.179 J03
- Issued
- Sep 19, 2012
- Abate by
- Nov 1, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(j)(3): Complete inspections of the crane was not being performed at intervals as generally defined in paragraph (j)(1)(ii)(b) of this section: a) Plant - Overhead & Gantry Cranes Complete inspections of the cranes were not performed on a monthly basis, on or about, 05/11/12.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.179 M01
- Issued
- Sep 19, 2012
- Abate by
- Nov 1, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(m)(1): A certification record which includes the date of inspection, the signature of the person who performed the inspection and an identifier for the ropes which were inspected were not being kept on file where readily available to appointed personnel: a) Plant - Overhead & Gantry Cranes Monthly inspections of the crane's wire rope with a certification record which included the date of the inspection, signature of the inspector, and an identifier of the rope were not performed, on or about, 05/11/12.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.179 L03 I
- Issued
- Sep 19, 2012
- Abate by
- Nov 1, 2012
- Penalty
- Initial $2,800 · Current $500 Reduced
General-duty citation text
29 CFR 1910.179(l)(3)(i): Unsafe condition(s) disclosed during the frequent or periodic inspection(s) required by 29 CFR 1910.179(j) were not corrected before operation of the crane(s) was resumed: a) Plant - NW 3 Ton Overhead Crane & SW 5 Ton Overhead Crane Cranes in operation with bows in the bridge section, on or about, 05/11/12. b) Plant - P&H 3 Ton Crane / Harrington 1 Ton Gantry Crane - Serial # 115607 / Harrington I Ton Gantry Crane - Serial # 195870 Cranes in operation with cracked control pendants, on or about, 05/11/12.
Recent events (2)
- — I (O) $500
- — Z (S) $2800
1910.212 A03 II
- Issued
- Sep 19, 2012
- Abate by
- Nov 1, 2012
- Penalty
- Initial $2,800 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposed an employee to injury, was not guarded: a) Lathe Department - Monarch Lathe - Inadequately guarded chuck and cutting device, on or about, 06/26/12. b) Fabrication Area - HTC Press Brake - Unguarded point of operation on press brake, on or about, 06/26/12. c) Lathe Department - Bridgeport/Acra Mills - Unguarded screw drill devices, on or about, 08/03/12. d) Lathe Department - Leblond Lathe - Inadequately guarded point of operation on lathe, on or about, 08/03/12.
Recent events (2)
- — I (S) $2000
- — Z (S) $2800
1910.1200 H01
- Issued
- Sep 19, 2012
- Abate by
- Nov 1, 2012
- Penalty
- Initial $2,100 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.1200(h)(1): The employer did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard the employees had not previously been trained about was introduced into their work area a) Throughout Shop - Employees were trained in accordance with the standard despite the use of Xylene thinner, gear oil, propane, oxygen, acetylene etc; on or about, 08/03/12.
Recent events (2)
- — I (S) $1500
- — Z (S) $2100
1910.179 G01 V
- Issued
- Sep 19, 2012
- Abate by
- Oct 11, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(g)(1)(v): Pendant control box(es) were not clearly marked for identification of functions: a) Plant - Jib Cranes N-1, N-7, S-1, & S-2 Pendant control boxe's operational functions were not clearly marked, on or about, 05/11/12.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Vincent Corporation
View Vincent Corporation's full OSHA safety record →
More inspections in this industry (NAICS 333294)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334477536.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.