Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BRINKEN CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BRINKEN CONSTRUCTION in 3921 S. US HIGHWAY 301, RIVERVIEW, FL 33578 (NAICS 237110). OSHA activity number 334484938.

Watch Brinken Construction — free Get an email when a new federal OSHA severe-injury report for Brinken Construction is published. One employer, no account, unsubscribe in one click.
Site address
3921 S. US HIGHWAY 301
City
RIVERVIEW
State
FL
ZIP
33578
Mailing
4616 MCBRIDE CT, LAND O LAKES, FL 34639
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
12
Ownership type
A

3 citations on file for this inspection.

1926.651 J02

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 13, 2012
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.651(j)(2): Employees were not protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations, or by a combination of both if necessary.    a. At the site on or about 05/15/2012, employees were exposed to a struck by hazard, in that,  the spoil pile was stored at the edge of the trench.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.651 C02

Deleted Serious Gravity 10 3 exposed
Issued
Jul 13, 2012
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:     a. For employees working in a trench 7 feet deep, 7 feet wide, 25 feet longat the site on 05/15/12.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1926.652 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 13, 2012
Penalty
Initial $28,000 · Current $5,000 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c). The employer had not complied with the provisions of 29 CFR 1926.652(b)(1)(i)     a.  At the site, employees are exposed to a cave in hazard, in that; no protective system was installed in a trench 7 feet deep, 7 feet wide and 25 feet long. The south trench wall was constructed at an 85 degree angle. The North trench wall was constructed at a 58.8 degree angle in type C soil, on or about 05/15/12.
Recent events (2)
  • — I (S) $5000
  • — Z (W) $28000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334484938.