ELLSINORE, MO ·
OSHA Inspection: M&Z PALLET LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of M&Z PALLET LLC in RR 2 COUNTY ROAD 340, ELLSINORE, MO 63937 (NAICS 321920). OSHA activity number 334489143.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- M&Z PALLET LLC
- Site address
- RR 2 COUNTY ROAD 340
- City
- ELLSINORE
- State
- MO
- ZIP
- 63937
- Mailing
- P.O. BOX 366, ELLSINORE, MO 63937
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321920
- Employees
- 5
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.213 G01
- Issued
- Jun 11, 2012
- Abate by
- Jul 2, 2012
- Penalty
- Initial $1,700 · Current $1,190 Reduced
General-duty citation text
29 CFR 1910.213(g)(1): Swing cutoff saw(s) were not provided with an automatically adjusting hood that completely enclosed the upper half of the saw, the arbor end, and the point of operation at all positions of the saw: At the time of the inspection, the swing cut-off saw was used without a guard to cover the point of operation at all positions of the saw.
Recent events (2)
- · I (S) $1190
- · Z (S) $1700
1910.303 B01 VII
- Issued
- Jun 11, 2012
- Abate by
- Jul 2, 2012
- Penalty
- Initial $1,700 · Current $1,190 Reduced
General-duty citation text
29 CFR 1910.303(b)(1)(vii): Electrical equipment was not free of recognized hazards that was likely to cause death or serious physical harm to employees. Safety of equipment was not determined using considerations for classification by type, size, voltage, current capacity, or specific use. At the time of the inspection, the main electrical box containing 440 volt service was operated with one of the three hot leads jumpered with copper wire instead of being protected with a current limiting fuse.
Recent events (2)
- · I (S) $1190
- · Z (S) $1700
1910.178 M05 I
- Issued
- Jun 11, 2012
- Abate by
- Jul 2, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(m)(5)(i): When powered industrial trucks were left unattended, load engaging means were not fully lowered, controls were not neutralized, power was not shut off, and brakes were not set At the time of the inspection, the employer operated the Hyster Model 80 forklift without a parking brake.