Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,473Inspections Most recent open 2026-07-28 Last loaded 2026-07-31

OSHA Inspection: AIR LIQUIDE AMERICA SG, LLC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of AIR LIQUIDE AMERICA SG, LLC in 7425 HIGHWAY 190 W, PORT ALLEN, LA 70767 (NAICS 325120). OSHA activity number 334491537.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AIR Liquide America SG, LLC — free Get an email when a new federal OSHA severe-injury report for AIR Liquide America SG, LLC is published. One employer, no account, unsubscribe in one click.
Site address
7425 HIGHWAY 190 W
City
PORT ALLEN
State
LA
ZIP
70767
Mailing
6141 EASTON RD. BLDG. #1, PLUMSTEADVILLE, PA 18949
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325120
Employees
3
Ownership type
A

3 citations on file for this inspection.

1910.102 A

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Oct 11, 2012
Abate by
Oct 21, 2012
Penalty
Initial $4,675 · Current $0 Reduced

Hazardous substances 00400070

29 CFR 1910.102(a) The in-plant transfer, handling, storage, and utilization of acetylene in cylinders was not in accordance with Compressed Gas Association Pamphlet G-1-1966, which is incorporated by reference as specified in 29 CFR 1910.6:    a) At 7425 Highway 190 West, Port Allen, LA; the employer allowed acetylene cylinders to be stored in an open yard area where they are subject to direct sunlight and high temperatures without shade and/or covering.  This condition was determined on or about May 23, 2012, during the investigation of a fire/explosion event that occurred at the site on May 21, 2012 where acetylene cylinders caught fire and exploded.  The acetylene cylinder(s) (P/C 350-75; Barcode 011431996) directly involved in the event had been stored in the outdoor area for 20 days and was subject to hot outdoor temperatures (a high of 90 degrees Fahrenheit).      Reference Standard CGA G-1--2009 Acetylene; Section 5.2: Rules for storing acetylene cylinders: When storing acetylene cylinders outdoors, they should be protected from the ground to prevent bottom corrosion.  During the winter, cylinders stored in the open should be protected against accumulations of ice or snow. In summer, charged cylinders stored in the open should be screened against the direct rays of the sun in those localities where extreme temperatures prevail.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4675

1910.157 E02

Serious Gravity 1 4 instances 3 exposed
Issued
Oct 11, 2012
Abate by
Oct 21, 2012
Penalty
Initial $2,805 · Current $2,805
29 CFR 1910.157(e)(2) Portable fire extinguishers were not visually inspected at least monthly:    a) At 7425 Highway 190 West, Port Allen, LA; the employer did not ensure that all portable fire extinguishers were visually inspected at least monthly.  This condition was observed on or about May 23, 2012, in the Loading Dock Area where portable fire extinguishers (AMEREX ABC Dry Chemical, Model A411), provided for employee use, had not received a required monthly visual inspection since March 2012.
Recent events (2)
  • — I (S) $2805
  • — Z (S) $2805

1910.178 C02 V

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Oct 11, 2012
Abate by
Oct 21, 2012
Penalty
Initial $4,675 · Current $0 Reduced

Hazardous substances 00400070D150

29 CFR 1910.178(c)(2)(v)  Power-operated industrial trucks designated as DS, ES, GS or LPS were not used in locations where hazardous liquids in sealed containers or liquefied or compressed gases in containers were being handled and stored:    a) At 7425 Highway 190 West, Port Allen, LA; the employer allowed employees to operate a diesel engine powered forklift truck in areas designated by the employer as a Class I Division 2 hazardous location.  This condition was determined on or about May 23, 2012, during the investigation of a fire/explosion event that occurred at the site on May 21, 2012 where acetylene cylinders caught fire and exploded.  A Harlo industrial forklift truck (Model HP8500; S/N 101449) was operated in the Maintenance/Yard area just prior to the incident, approximately 40 feet from the exploding acetylene cylinder and is used throughout the area on daily basis.  The forklift truck was not approved for Class I Division 2 hazardous locations where flammable compressed gases are handled and stored.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4675

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334491537.