VALDOSTA, GA —
OSHA Inspection: CAUTHAN CONSTRUCTION CO., INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CAUTHAN CONSTRUCTION CO., INC. in 1501 N. PATTERSON ST., VALDOSTA, GA 31601 (NAICS 238110). OSHA activity number 334501335.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CAUTHAN CONSTRUCTION CO., INC.
- Site address
- 1501 N. PATTERSON ST.
- City
- VALDOSTA
- State
- GA
- ZIP
- 31601
- Mailing
- 1321 WEST HILL AVE.,, VALDOSTA, GA 31601
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238110
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 G01
- Issued
- Sep 21, 2012
- Penalty
- Initial $3,500 · Current $5,250
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. a) North side of the building, 2nd floor deck, on or about May 22, 2012, an employee was working from the outrigger of a tubular welded frame scaffold without guardrails and no other means of fall protection, exposing him up to a 14-foot fall hazard. ABATEMENT CERTIFICATION IS NOT REQUIRED
Recent events (2)
- — I (S) $5250
- — Z (S) $3500
1926.501 B01
- Issued
- Sep 21, 2012
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) North side of the building, 2nd floor, on or about May 22, 2012, employees were working from an unguarded 2nd floor stepping on/off the stairway, exposing employees to a 12 foot fall hazard. ABATEMENT CERTIFICATION IS NOT REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $3500
1926.1052 B01
- Issued
- Sep 21, 2012
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1052(b)(1): Except during stairway construction, foot traffic is prohibited on stairways with pan stairs where the treads and/or landings are to be filled in with concrete or other material at a later date, unless the stairs are temporarily fitted with wood or other solid material at least to the top edge of each pan. Such temporary treads and landings shall be replaced when worn below the level of the top edge of the pan. a) North side of the building, on or about May 22, 2012, the metal stair pans and landings were not filled in with concrete, exposing employees trip and fall hazards. ABATEMENT CERTIFICATION IS NOT REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $3500
1926.1052 C01
- Issued
- Sep 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with: 1926.1052(1) a) North sides of the building, on May 22, 2012, the employer did not provide a handrail or stairrail system along the unprotected sides of a stairway to prevent employees from falling to lower level, exposing employees to a fall hazards. ABATEMENT CERTIFICATION IS NOT REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Cauthan Construction CO., INC.
View Cauthan Construction CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238110)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334501335.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.