LUDOWICI, GA ·
OSHA Inspection: EMEGC, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of EMEGC, INC. in STATE ROAD 57, LUDOWICI, GA 31316 (NAICS 237130). OSHA activity number 334502135.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EMEGC, INC.
- Site address
- STATE ROAD 57
- City
- LUDOWICI
- State
- GA
- ZIP
- 31316
- Mailing
- 3615 E. LAKE AVE, TAMPA, FL 33610
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237130
- Employees
- 8
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.268 H07
- Issued
- Sep 21, 2012
- Abate by
- Oct 5, 2012
- Penalty
- Initial $4,900 · Current $3,185 Reduced
General-duty citation text
29 CFR 1910.268(h)(7): When a ladder is supported by an aerial strand, and ladder hooks or other supports are not being used, the ladder shall be extended at least 2 feet above the strand and shall be secured to it (e.g. lashed or held by a safety strap around the strand and ladder side rail). When a ladder is supported by a pole, it shall be securely lashed to the pole unless the ladder is specifically designed to prevent movement when used in this application. a) At the job site, on or about May 23, 2012, an employee was accessing an area of the guyed wires using a 24-foot extension ladder, while it was leaning against the guy wires without being secured in placed and not being 2 feet above the strand, exposing the employee to a fall hazard. ABATEMENT CERTIFICATION AND DOCUMENTATION IS NOT REQUIRED
Recent events (2)
- · I (O) $3185
- · Z (S) $4900
1910.305 A02 X
- Issued
- Sep 21, 2012
- Penalty
- Initial $2,100 · Current $1,365 Reduced
General-duty citation text
29 CFR 1910.305(a)(2)(x): Flexible cords and cables shall be protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points. a) At the job site, on or about May 23, 2012, an extension cord supplying electrical power for portable hand held tools used by employees was located across driveway and subject to damage by vehicular traffic, exposing employees to electrical shock hazards. ABATEMENT CERTIFICATION IS NOT REQUIRED
Recent events (2)