OSHA Inspection: FANTASY FINISHES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FANTASY FINISHES, INC. in 1318 FOREST, EVANSTON, IL 60201 (NAICS 238320). OSHA activity number 334502358.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fantasy Finishes, INC. for free Get an email when a new federal OSHA severe-injury report for Fantasy Finishes, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1318 FOREST
City
EVANSTON
State
IL
ZIP
60201
Mailing
P.O. BOX 3832, BARRINGTON, IL 60011
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238320
Employees
2
Ownership type
Private (A)

4 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 12, 2012
Abate by
Jun 13, 2012
Penalty
Initial $2,800 · Current $1,000 Reduced
29 CFR 1926.501(b)(13): Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph (b) Note:  If using these systems was infeasible or created a greater hazard, the employer should develop and implement a fall protection plan meeting the requirements of paragraph (k) of 1926.502.    a) Fall protection was not used while work was conducted from a pitched roof deck having a ground to eave height of approximately 25 feet.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2800

1926.1053 A08

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 12, 2012
Abate by
Jun 13, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(a)(8): A metal spreader or locking device was not provided on each stepladder to hold the front and back sections in an open position when the ladder was being used:    a) A stepladder was used without having the metal spreader or locking device holding the stepladder in an open position.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.1053 B04

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Jun 12, 2012
Abate by
Jun 13, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:    a) A stepladder was used without its metal spreaders or locking devices in the open position.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 12, 2012
Abate by
Jun 13, 2012
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    a) An extension ladder did not extend at least 3 feet above the landing surface of a pitched roof having a ground to eave height of approximately 25 feet.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 334502358.