Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: SCA TISSUE NORTH AMERICA

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SCA TISSUE NORTH AMERICA in 1 RIVER STREET, SOUTH GLENS FALLS, NY 12803 (NAICS 322121). OSHA activity number 334505138.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch SCA Tissue North America for free Get an email when a new federal OSHA severe-injury report for SCA Tissue North America is published. One employer, no account, unsubscribe in one click.
Site address
1 RIVER STREET
City
SOUTH GLENS FALLS
State
NY
ZIP
12803
Mailing
1 RIVER STREET, SOUTH GLENS FALLS, NY 12803
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322121
Employees
277
Ownership type
Private (A)

4 citations on file for this inspection.

1910.303 G02 I

Serious Gravity 10 2 instances 50 exposed
Issued
Oct 23, 2012
Abate by
Nov 14, 2012
Penalty
Initial $6,300 · Current $6,300
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    a)  Building 9 - On or about July 11, 2012, an electrical junction box was not adequately mounted on the wall  exposing live electrical components.     b)  Burner Room - On or about July 20, 2012, live electrical wires were not guarded by means of an electrical box and were setting on an accumulation of combustible paper towel dust (ST1).
Recent events (3)
  • · F (S) $6300
  • · C (S) $6300
  • · Z (S) $6300

1910.305 G01 IV

Serious Gravity 5 2 instances 50 exposed
Issued
Oct 23, 2012
Abate by
Nov 14, 2012
Penalty
Initial $3,825 · Current $6,300
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv):    a)  Building 9 Mezzanine - On or about July 11, 2012, an extension cord was used as permanent wiring for a mounted Dayton commercial air circulator (Serial # 11434159).    b)  Building 9 Mezzanine - On or about July 11, 2012, a flexible cord was used for permanently fixed lighting.
Recent events (3)
  • · F (S) $6300
  • · C (S) $3825
  • · Z (S) $3825

1910.22 A01

Serious Gravity 10 4 instances 60 exposed
Issued
Oct 23, 2012
Abate by
Nov 14, 2012
Penalty
Initial $6,300 · Current $6,300
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition:    a)  Building 9 - On or around May 30 and July 11 of  2012, structural supports, pipes, fixtures, ductwork, walls, room roofing, floors and equipment were not kept free of hazardous accumulation of combustible dust.    b)  Building 8 - On or around May 30, July 11 and July 20 of 2012, structural supports, pipes, fixtures, equipment and ductwork were not kept free of hazardous accumulation of combustible dust.    c)  Building 15 - On or around May 30 and July 20 of 2012, structural supports, pipes, fixtures, equipment and ductwork were not kept free of hazardous accumulation of combustible dust.    d)  Burner/Control Room - On or around May 30 and July 20 of 2012, structural supports, pipes, equipment, and ductwork were not kept free of hazardous accumulation of combustible dust.
Recent events (3)
  • · F (S) $6300
  • · C (S) $6300
  • · Z (S) $6300

1910.307 C

Serious Gravity 10 2 instances 50 exposed
Issued
Oct 23, 2012
Abate by
Nov 14, 2012
Penalty
Initial $6,300 · Current $0 Reduced
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location:    a)  Building 9 - On or around May 30 and July 11 of 2012, employees conducted a blow down cleaning procedure for tissue paper dust, a Class II Group G Explosive Dust, suspending the dust in air.  General purpose wiring, breaker panel boxes, disconnect switches, receptacles and electric motors were not dust-tight ignition proof and approved for Class II Division 1 locations.    b)  Building 15 - On or around May 30 and July 20, 2012, employees conduct a blow down cleaning procedure for tissue paper dust, a Class II Group G Explosive Dust, suspending the dust in the air.  General purpose wiring, breaker panel boxes, disconnect switches, receptacles and electric motors were not dust-tight ignition proof and approved for Class II Division 1 locations.
Recent events (3)
  • · F (S) $0
  • · C (S) $6300
  • · Z (S) $6300

View SCA Tissue North America's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 334505138.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.