ROCKFORD, IL —
OSHA Inspection: CJ WHITEFORD ROOFING INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CJ WHITEFORD ROOFING INC. in 5903 CREEKSIDE LANE, ROCKFORD, IL 61114 (NAICS 238160). OSHA activity number 334508751.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CJ WHITEFORD ROOFING INC.
- Site address
- 5903 CREEKSIDE LANE
- City
- ROCKFORD
- State
- IL
- ZIP
- 61114
- Mailing
- 5218 EAST DRIVE, LOVES PARK, IL 61111
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 2
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Jun 21, 2012
- Penalty
- Initial $2,000 · Current $920 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph (b) Employees tearing off a residential roof and replacing in kind approximately 8 feet abave grade on a 5:12 pitched roof were not utilizing any method of fall protection. There is no abatement certification or documentation required for this item.
Recent events (2)
- — I (S) $920
- — Z (S) $2000
1926.1053 B01
- Issued
- Jun 21, 2012
- Penalty
- Initial $1,200 · Current $200 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladders length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: An extension ladder used by employees to gain access and egress to a residential roof did not extend a minimum of 3 feet above the surface being accessed. There is no abatement certification or documentation required for this item.
Recent events (2)
- — I (S) $200
- — Z (S) $1200
More inspections in this industry (NAICS 238160)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334508751.