SYRACUSE, NY —
OSHA Inspection: WARD STEEL, INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of WARD STEEL, INC in SU SOUTH LIBRARY WAREHOUSE, 1556 JAMESVILLE AVENUE, SYRACUSE, NY 13210 (NAICS 238120). OSHA activity number 334512415.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WARD STEEL, INC
- Site address
- SU SOUTH LIBRARY WAREHOUSE, 1556 JAMESVILLE AVENUE
- City
- SYRACUSE
- State
- NY
- ZIP
- 13210
- Mailing
- 4591 MORGAN PLACE, LIVERPOOL, NY 13090
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.760 A01
- Issued
- Jul 27, 2012
- Abate by
- Aug 1, 2012
- Penalty
- Initial $5,390 · Current $2,695 Reduced
General-duty citation text
29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems: a) North side of roof deck, on or about 5-30-12: Employee were installing metal roof decking while in a Controlled Decking Zone (CDZ) that did not meet specific requirements and/or qualify as a CDZ, without fall protection, exposing the employees to a fall hazard of 20 feet 11-1/2 inches.
Recent events (3)
- — J (S) $2695
- — C (S) $5390
- — Z (S) $5390
1926.760 C03
- Issued
- Jul 27, 2012
- Abate by
- Aug 1, 2012
- Penalty
- Initial $5,390 · Current $2,695 Reduced
General-duty citation text
29 CFR 1926.760(c)(3): The Controlled Decking Zone (CDZ) boundary designation was more than 90 feet (27.4 m) wide and more than 90 feet (27.4 m) deep from the leading edge: a) North side of roof deck, on or about 5-30-12: Employee were installing metal roof decking while in a Controlled Decking Zone (CDZ) that was wider than 90 feet and more than 90 feet away from the leading edge.
Recent events (3)
- — J (S) $2695
- — C (S) $5390
- — Z (S) $5390
1926.760 C04
- Issued
- Jul 27, 2012
- Abate by
- Aug 26, 2012
- Penalty
- Initial $5,390 · Current $5,390
General-duty citation text
29 CFR 1926.760(C)(4): Each employee working in a Controlled Decking Zone (CDZ) did not complete training in accordance with 1926.761: a) North side of roof deck, on or about 5-30-12: Employees were installing metal roof decking while in a Controlled Decking Zone (CDZ), without completing the training required for employees working in a CDZ.
Recent events (3)
- — J (S) $5390
- — C (S) $5390
- — Z (S) $5390
1926.761 C03 I
- Issued
- Jul 27, 2012
- Abate by
- Aug 26, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.761(C)(3)(i): Where a Controlled Decking Zone (CDZ) was being used, each employee was not provided training in the nature of the hazards associated with work within a Controlled Decking Zone (CDZ): a) North side of roof deck, on or about 5-30-12: Employees were installing metal roof decking while in a Controlled Decking Zone (CDZ) without the training necessary for employees to recognize the nature of the hazards associated with work within a CDZ.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1926.761 C03 II
- Issued
- Jul 27, 2012
- Abate by
- Aug 26, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.761(c)(3)(ii): Where a Controlled Decking Zone (CDZ) was being used, each employee was not provided training in the establishment, access, proper installation techniques and work practices required by 1926.760(c) and 1926.754(e): a) North side of roof deck, on or about 5-30-12: Employees were installing metal roof decking while in a Controlled Decking Zone (CDZ) without the training necessary for employees to recognize the nature of the hazards associated with work within a CDZ.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
More inspections at Ward Steel, INC