Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JOHNSON FILTRATION PRODUCTS INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of JOHNSON FILTRATION PRODUCTS INC. in 601 S ROSS, AMARILLO, TX 79106 (NAICS 313210). OSHA activity number 334517331.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Johnson Filtration Products INC. — free Get an email when a new federal OSHA severe-injury report for Johnson Filtration Products INC. is published. One employer, no account, unsubscribe in one click.
Site address
601 S ROSS
City
AMARILLO
State
TX
ZIP
79106
Mailing
P.O. BOX 30010, AMARILLO, TX 79120
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
313210
Employees
21
Ownership type
A

11 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 2 instances 21 exposed
Issued
Oct 15, 2012
Abate by
Oct 19, 2012
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.22(a)(1):     All places of employment, passageways, storerooms, and service rooms shall be kept clean and orderly and in a sanitary condition.        On or about 05/23/2012 Johnson Filtration Products Inc. did not ensure good housekeeping practices to eliminate slips, trips, fall, and fire ignition hazards to employees.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.147 C04 I

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Oct 15, 2012
Abate by
Oct 19, 2012
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i):     Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities.        On or about 05/23/2012 employees were observed performing routine maintenance on winding machines without controlling hazardous energy by ensuring that they were locked out or tagged out presenting electrocution, crushing, and amputation hazards to employees.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1910.157 C01

Serious Gravity 1 1 instance 21 exposed
Issued
Oct 15, 2012
Abate by
Oct 22, 2012
Penalty
Initial $1,200 · Current $720 Reduced
29 CFR 1910.157(c)(1):     Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries.      On or about 05/23/2012 portable fire extinguisher signage was present without a portable fire extinguisher making the fire extinguisher not readily accessible to employees in the event of fire.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1910.212 A03 II

Serious Gravity 10 5 instances 21 exposed
Issued
Oct 15, 2012
Abate by
Nov 28, 2012
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.212(a)(3)(ii):     Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle.        On or about 05/23/2012 Johnson Filtration Products Inc. did not provide guarding on multiple winding machines found  along the aisle of the shop floor presenting caught in hazards to employees that could result in caught in, crushing, and amputations to employees.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.213 H01

Serious Gravity 5 2 instances 1 exposed
Issued
Oct 15, 2012
Abate by
Oct 22, 2012
Penalty
Initial $2,400 · Current $1,440 Reduced
29 CFR 1910.213(h)(1):     The sides of the lower exposed portion of the blade of radial saws were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock.      On or about 05/23/2012 Johnson Filtration Products Inc. did not have guards in place to protect workers from hazards associated with radial arm saws such as: cuts, lacerations, and amputations.
Recent events (2)
  • — I (S) $1440
  • — Z (S) $2400

1910.215 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 15, 2012
Abate by
Oct 22, 2012
Penalty
Initial $2,400 · Current $1,440 Reduced
29 CFR 1910.215(b)(9):     The distance between the end of the safety guard peripheral member at the top exceeded one fourth inch.      On or about 05/23/2012 the end of the safety guard was 3/4in from the abrasive wheel exceeding the 1/4in allowed.  This excessive distance exposed employees to struck by and burn hazards from sparks and metal fragments being thrown at high speeds.
Recent events (2)
  • — I (S) $1440
  • — Z (S) $2400

1910.242 B

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 15, 2012
Abate by
Oct 19, 2012
Penalty
Initial $2,400 · Current $1,440 Reduced
29 CFR 1910.242(b):     Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.    On or about 05/23/2012 employees were observed using compressed air for cleaning purposes in excess of 30 p.s.i. without personal protective equipment to protect against flying debris that can cause foreign bodies to enter eyes and punctures.    On or about 05/23/2012 employees used compressed air for cleaning purposes in excess of 30 p.s.i. exposing employees to foreign bodies in eyes, puncture wounds, and lacerations from flying debris.
Recent events (2)
  • — I (S) $1440
  • — Z (S) $2400

1910.303 G02 I

Serious Gravity 5 2 instances 2 exposed
Issued
Oct 15, 2012
Abate by
Oct 19, 2012
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.303(g)(2)(i):     Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures.      On or about 05/23/2012 Johnson Filtration Products Inc. had two instances of exposed live electrical which exposed employees to electrocution.  a) A broken plug on an electrical outlet  b) Exposed wires on the underside of a winding machine
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.305 G01 I

Serious Gravity 5 1 instance 21 exposed
Issued
Oct 15, 2012
Abate by
Oct 22, 2012
Penalty
Initial $2,400 · Current $1,440 Reduced
29 CFR 1910.305(g)(1)(i):     Flexible cords and cables were not approved or conditions of use and location.    On or about 05/23/2012 temporary flexible cords were being used in place of permanent wiring presenting trips, slips, falls, electrical shock, and fire ignition hazards to employees.
Recent events (2)
  • — I (S) $1440
  • — Z (S) $2400

1910.305 G02 II

Serious Gravity 5 1 instance 21 exposed
Issued
Oct 15, 2012
Abate by
Oct 22, 2012
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.305(g)(2)(ii):     Flexible cords were not used only in continuous lengths without splice or tap.        On or about 05/23/2012 a flexible cord that was improperly spliced was used to power a portable cooler presenting electrocution hazards to employees.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.305 G02 III

Serious Gravity 5 2 instances 3 exposed
Issued
Oct 15, 2012
Abate by
Oct 19, 2012
Penalty
Initial $2,400 · Current $1,440 Reduced
29 CFR 1910.305(g)(2)(iii):     Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws.        On or about 05/23/2012 flexible cords were identified to have exposed wires due to improper strain relief apparatus exposing employees to electrocution hazards.
Recent events (2)
  • — I (S) $1440
  • — Z (S) $2400

View Johnson Filtration Products INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334517331.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.