Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STEEL STRUCTURES INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of STEEL STRUCTURES INC. in 8105 ENTERPRISE DR., WAUSAU, WI 54401 (NAICS 238120). OSHA activity number 334520731.

Watch Steel Structures INC. — free Get an email when a new federal OSHA severe-injury report for Steel Structures INC. is published. One employer, no account, unsubscribe in one click.
Site address
8105 ENTERPRISE DR.
City
WAUSAU
State
WI
ZIP
54401
Mailing
8105 ENTERPRISE DR., WAUSAU, WI 54401
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
7
Ownership type
A

8 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2100.00 Reduced
OSH ACT of 1970 Section (5)(a)(1):     Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious harm:     In that, employees were exposed to the hazard of falling from heights when elevated by the Catepillar V50C fork lift in a shop fabricated personnel basket to perform tasks, such as repairing overhead lights, inspecting overhead hoists, etc.       On or around 5/31/2012, the employer did not ensure that the employee was working from a personnel platform which was secured to the mast.  The platform was elevated to 18 to 20 feet when the forklift rolled down and off a truck bed and struck a shear press, causing the platform to partially slide off the forks.                                                                           Abatement Certification and Documentation is required.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $2800

1910.178 A04

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2100.00 Reduced
29 CFR 1910.178(a)(4):     Modifications and additions which affected capacity and safe operation were performed by the customer or user without manufacturers written approval:    a.)  The employer used a shop-fabricated man basket over the forks of Catepillar V50C powered industrial truck to lift an employee 20 feet high to change light fixtures.  The fork lift was not approved by Catepillar for use with this man basket.                                                                   Abatement Certification and Documentation is required.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $2800

1910.178 A06

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(a)(6):     The employer did not ensure that all nameplates and markings were in place:    (a.)  Hyster S40C, 4000# capacity fork lift, SN C2D17648V, did not have legible information on the nameplate, including the serial number and safe usage specifications.                                                    Abatement Certification and Documentation is required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2100.00 Reduced
29 CFR 1910.178(l):     Operators were not trained in the safe operation of powered industrial trucks:      a.)  On or before 5/31/2012, the company had not evaluated nor confirmed training necessary to operate powered industrial trucks had been completed for each employee using company trucks.  The training provided to employees by previous employers was not specific to the current company fork lift usage.  No additional training was conducted by the company.  Equipment used in the company included:    *    Catepillar V50C, 5000# capacity fork lift,  SN 39Y02284  *    Catepillar GPL40 or GPL45, SN 1CN90316, 9000 # capacity fork lift,  *    Hyster S40C, 4000# capacity fork lift, SN C2D17648V, and  *    Company manufactured man-basket, and other equipment used with the fork lifts.                                               Abatement Certification and Documentation is required.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $2800

1910.178 M05 I

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(m)(5)(i):     When a powered industrial truck is left unattended, load engaging means were not fully lowered, controls were not neutralized, power was not shut off, and brakes set.      a.)  On 5/31/2012, a Catepillar V50C fork lift used to lift a man basket 20 feet high while parked on the bed of a Mack truck was left unattended with the load still extended and the power shut off.  The emergency brake was not set nor wheels blocked as the operator left the fork lift to access gloves per the maintenance supervisor's request.   The operator was dismounted from the flat bed and was on the floor surface with his back to the fork lift in order to get to the gloves.                                             Abatement Certification and Documentation is required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 M06

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(m)(6):     A safe distance was not maintained from the edge of ramps or platforms while on any elevated dock, or platform or freight car    a.)  On 5/31/2012, a Catepillar forklift was operated on top of and on the end of a Mack truck bed.  The section of the truck bed past the axles was deformed from the loading weight of the equipment, causing the forklift to move forward and over the edge of the truck bed.                                     Abatement Certification and Documentation is required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 Q01

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(q)(1):     Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel:      a.)  On or before 5/31/2012, a Catepillar V50C was used daily in the shop for lifting equipment and/or materials without adequate brakes.                                           Abatement Certification and Documentation is required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 Q07

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(q)(7):     Industrial trucks were not examined before being placed in service, or were placed in service if the examination showed conditions adversely affecting the safety of the vehicle      a.)  On or before 5/31/2012, there was no requirement to examine fork lift trucks prior to used for the shift.  Employees using company fork lifts knew of multiple mechanical problems, including bad brakes, and the fork lifts  were never removed from service nor repaired until after an accident occurred.                                    Abatement Certification and Documentation is required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View STEEL STRUCTURES INC.'s full OSHA safety record →