PITTSBURGH, PA ·
OSHA Inspection: SPAID CORPORATION, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SPAID CORPORATION, INC. in 3315 PENN AVENUE, PITTSBURGH, PA 15201 (NAICS 332999). OSHA activity number 334521960.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SPAID CORPORATION, INC.
- Site address
- 3315 PENN AVENUE
- City
- PITTSBURGH
- State
- PA
- ZIP
- 15201
- Mailing
- 3315 PENN AVENUE, PITTSBURGH, PA 15201
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 10
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.24 H
- Issued
- Jul 20, 2012
- Abate by
- Jul 27, 2012
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1910.24(h): Standard railings were not provided on the open sides of all exposed stairways and stair platforms: (a) Facility, New Building: On or about May 30, 2012, the handrail to the flight of steps (6 risers) to the upper level was badly damaged and bent.
Recent events (2)
- · I (S) $720
- · Z (S) $1200
1910.23 C01
- Issued
- Jul 20, 2012
- Abate by
- Aug 10, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: Note: Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard. (a) Facility, New Building: On or about May 30, 2012, there was no guardrail at the edge of the upper level. The fall hazard to the lower level was 48 1/2 to 49 1/4 inches.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.110 F07
- Issued
- Jul 20, 2012
- Abate by
- Jul 23, 2012
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.110(f)(7): LP gas container storage location(s) were not provided with at least one approved portable fire extinguisher having a minimum rating of 8-B, C: (a) Facility, Outside Propane Storage Area by the Scale House: There were 8 full propane tanks located in this area and there was no B, C fire extinguisher located in this area.
Recent events (2)
- · I (S) $1200
- · Z (S) $2000
1910.110 F02 I
- Issued
- Jul 20, 2012
- Abate by
- Jul 23, 2012
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1910.110(f)(2)(i): 29 CFR 1910.110(f)(2)(i): LP gas container(s) in storage were not located so as to minimize exposure to excessive temperature rise, physical damage, or tampering by unauthorized persons: (a) Facility, Outside by the Scale House: There were 8 propane gas cylinders located in this area, that were not protected from physical damage.
Recent events (2)
- · I (S) $720
- · Z (S) $1200
1910.178 L
- Issued
- Jul 20, 2012
- Abate by
- Aug 10, 2012
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1910.178(l): Operators were not trained in the safe operation of powered industrial trucks: (a) Facility: On or about May 30, 2012, employees that operated the Nissan and Toyota forklifts were not trained to safely operate them.
Recent events (2)
- · I (S) $960
- · Z (S) $1600
1910.178 Q01
- Issued
- Jul 20, 2012
- Abate by
- Aug 10, 2012
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel: (a) Facility: On or about May 30, 2012, the Nissan forklift that was being operated, had its seat belt removed. (b) Facility: On or about May 30, 2012, the Nissan forklift that was being operated, had a non functioning backup beeper. (c) Facility: On or about May 30, 2012, there was a missing side panel on the Nissan forklift.
Recent events (2)
- · I (S) $720
- · Z (S) $1200
1910.212 A01
- Issued
- Jul 20, 2012
- Abate by
- Aug 10, 2012
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by: (a) Facility, Aluminum Yard: On or about May 30, 2012, an employee would operate the siding bailer with its guard in the full upright position. In addition, this guard was not interlocked to prevent the hydraulic ram from operating without the guard being fully closed. (b) Facility, New Building, Upper Level: On or about May 30, 2012, an employee would operate the Union Environmental bailer with its guard in the full upright position. In addition, this guard was not interlocked to prevent the hydraulic ram from operating without the guard being fully closed. (c) Facility, New Building, Upper Level: On or about May 30, 2012, an employee would operate the Quality products compactor with its guard in the full upright position. In addition, this guard was not interlocked to prevent the hydraulic ram from operating without the guard being fully closed.
Recent events (2)
- · I (S) $1200
- · Z (S) $2000
1910.157 E03
- Issued
- Jul 20, 2012
- Abate by
- Jul 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: (a) Facility, Old Building: On or about May 30, 2012, the 2A , 10BC fire extinguisher located by th entrance of the building, was last serviced in 2009..
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.303 F02
- Issued
- Jul 20, 2012
- Abate by
- Aug 10, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: (a) Facility, Old Building: On or about May 30, 2012, there were electrical circuit breakers located just inside the overhead garge door that were not marked as to what they controlled.
Recent events (2)
- · I (O) $0
- · Z (O) $0