Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: SPAID CORPORATION, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SPAID CORPORATION, INC. in 3315 PENN AVENUE, PITTSBURGH, PA 15201 (NAICS 332999). OSHA activity number 334521960.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Spaid Corporation, INC. for free Get an email when a new federal OSHA severe-injury report for Spaid Corporation, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3315 PENN AVENUE
City
PITTSBURGH
State
PA
ZIP
15201
Mailing
3315 PENN AVENUE, PITTSBURGH, PA 15201
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
10
Ownership type
A

9 citations on file for this inspection.

1910.24 H

Serious Gravity 1 1 instance 3 exposed
Issued
Jul 20, 2012
Abate by
Jul 27, 2012
Penalty
Initial $1,200 · Current $720 Reduced
29 CFR 1910.24(h): Standard railings were not provided on the open sides of all exposed stairways and stair platforms:          (a) Facility, New Building:  On or about May 30, 2012, the handrail to the flight of steps (6 risers) to the upper level was badly damaged and bent.
Recent events (2)
  • · I (S) $720
  • · Z (S) $1200

1910.23 C01

Serious Gravity 1 1 instance 2 exposed
Issued
Jul 20, 2012
Abate by
Aug 10, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:      Note:  Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard.    (a) Facility, New Building:  On or about May 30, 2012, there was no guardrail at the edge of the upper level.  The fall hazard to the lower level was 48 1/2 to 49 1/4 inches.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.110 F07

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 20, 2012
Abate by
Jul 23, 2012
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.110(f)(7): LP gas container storage location(s) were not provided with at least one approved portable fire extinguisher having a minimum rating of 8-B, C:            (a) Facility, Outside Propane Storage Area by the Scale House:  There were 8 full propane tanks located in this area and there was no B, C fire extinguisher located in this area.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2000

1910.110 F02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 20, 2012
Abate by
Jul 23, 2012
Penalty
Initial $1,200 · Current $720 Reduced
29 CFR 1910.110(f)(2)(i): 29 CFR 1910.110(f)(2)(i):  LP gas container(s) in storage were not located so as to minimize exposure to excessive temperature rise, physical damage, or tampering by unauthorized persons:            (a) Facility, Outside by the Scale House:  There were 8 propane gas cylinders located in this area, that were not protected from physical damage.
Recent events (2)
  • · I (S) $720
  • · Z (S) $1200

1910.178 L

Serious Gravity 5 2 instances 3 exposed
Issued
Jul 20, 2012
Abate by
Aug 10, 2012
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.178(l): Operators were not trained in the safe operation of powered industrial trucks:            (a) Facility:  On or about May 30, 2012, employees that operated the Nissan and Toyota forklifts were not trained to safely operate them.
Recent events (2)
  • · I (S) $960
  • · Z (S) $1600

1910.178 Q01

Serious Gravity 1 1 instance 3 exposed
Issued
Jul 20, 2012
Abate by
Aug 10, 2012
Penalty
Initial $1,200 · Current $720 Reduced
29 CFR 1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel:    (a)  Facility:  On or about May 30, 2012, the Nissan forklift that was being operated, had its seat belt removed.    (b)  Facility:  On or about May 30, 2012, the Nissan forklift that was being operated, had a non functioning backup beeper.    (c)  Facility:  On or about May 30, 2012, there was a missing side panel on the Nissan forklift.
Recent events (2)
  • · I (S) $720
  • · Z (S) $1200

1910.212 A01

Serious Gravity 5 3 instances 4 exposed
Issued
Jul 20, 2012
Abate by
Aug 10, 2012
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by:            (a)  Facility, Aluminum Yard:  On or about May 30, 2012, an employee would operate the siding bailer with its guard in the full upright position.  In addition, this guard was not interlocked to prevent the hydraulic ram from operating without the guard being fully closed.     (b)  Facility, New Building, Upper Level:  On or about May 30, 2012, an employee would operate the Union Environmental bailer with its guard in the full upright position.  In addition, this guard was not interlocked to prevent the hydraulic ram from operating without the guard being fully closed.       (c)  Facility, New Building, Upper Level:  On or about May 30, 2012, an employee  would operate the Quality products compactor with its guard in the full upright position.  In addition, this guard was not interlocked to prevent the hydraulic ram from operating without the guard being fully closed.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2000

1910.157 E03

Other-than-serious 1 instance 2 exposed
Issued
Jul 20, 2012
Abate by
Jul 27, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:            (a) Facility, Old Building:  On or about May 30, 2012, the 2A , 10BC fire extinguisher located by th entrance of the building, was last serviced in 2009..
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.303 F02

Other-than-serious 1 instance 2 exposed
Issued
Jul 20, 2012
Abate by
Aug 10, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:            (a) Facility, Old Building:  On or about May 30, 2012, there were electrical circuit breakers located just inside the overhead garge door that were not marked as to what they controlled.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334521960.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.