OSHA Inspection: VANGUARD CONTRACTORS, LP

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of VANGUARD CONTRACTORS, LP in 814 11TH STREET, BLANCO, TX 78606 (NAICS 236220). OSHA activity number 334526944.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vanguard Contractors, LP — free Get an email when a new federal OSHA severe-injury report for Vanguard Contractors, LP is published. One employer, no account, unsubscribe in one click.
Site address
814 11TH STREET
City
BLANCO
State
TX
ZIP
78606
Mailing
P.O. BOX 80, TEMPLE, TX 76503
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
25
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 4 exposed
Issued
Jun 15, 2012
Abate by
Jun 18, 2012
Penalty
Initial $2,160 · Current $2,160
OSH ACT of 1970 Section (5)(a)(1):     The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazards of impalement from protruding rebar in the ground.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the obligation, including describing the steps that it is taking to ensure protruding rebar is removed, bent, or capped to prevent an impalement hazard.
Recent events (2)
  • — I (S) $2160
  • — Z (S) $2160

1926.405 B02

Other-than-serious 1 instance 1 exposed
Issued
Jun 15, 2012
Abate by
Jun 18, 2012
Penalty
Initial $2,800 · Current $860 Reduced
29 CFR 1926.405(b)(2):     Covers and canopies. All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.    On or about 31 May 2012, and at times prior thereto, the employer did not ensure a cover was installed on a breaker panel located within the general contractor's office, exposing workers to electrical shock or electrocution by live components at approximately 220 volts.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure all electrical panels are covered in order to protect workers from live components.
Recent events (2)
  • — I (O) $860
  • — Z (S) $2800

1926.417 B

Other-than-serious 1 instance 2 exposed
Issued
Jun 15, 2012
Abate by
Jun 18, 2012
Penalty
Initial $2,800 · Current $860 Reduced
29 CFR 1926.417(b):     Equipment and circuits. Equipment or circuits that are deenergized shall be rendered inoperative and shall have tags attached at all points where such equipment or circuits can be energized.    On or about 31 May 2012, and at times prior thereto, the employer did not lockout or tagout the electrical source for a de-energized breaker panel that had the cover removed to "air out" the components which were located within the general contractor's office, exposing workers to electrical shock or electrocution by live components at approximately 220 volts.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure all de-energized electrical panels are locked out and/or tagged out during repair or maintenence to such in order to protect workers from live components.
Recent events (2)
  • — I (O) $860
  • — Z (S) $2800

1926.1053 B04

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Jun 15, 2012
Abate by
Jun 18, 2012
Penalty
Initial $1,200 · Current $0 Reduced
29 CFR 1926.1053(b)(4):     Ladders shall be used only for the purpose for which they were designed.    On or about 31 May 2012, and at times prior thereto, a worker was utilizing a folding 8 foot fiberglass ladder in a manner that it was not designed for.  The worker had it folded and leaning against the wall while he was standing on the 5th rung up from the ground, knocking out the window frame as part of demolition activities.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure ladders on the job site are used for the purpose for which they were designed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1200