OSHA Inspection: MIDWEST FASTENERS CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MIDWEST FASTENERS CORPORATION in 133 CORPORATE DRIVE, JOHNSTOWN, NY 12095 (NAICS 423710). OSHA activity number 334529351.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Midwest Fasteners Corporation — free Get an email when a new federal OSHA severe-injury report for Midwest Fasteners Corporation is published. One employer, no account, unsubscribe in one click.
Site address
133 CORPORATE DRIVE
City
JOHNSTOWN
State
NY
ZIP
12095
Mailing
133 CORPORATE DRIVE, JOHNSTOWN, NY 12095
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423710
Employees
200
Ownership type
A

7 citations on file for this inspection.

1910.37 B01

Serious Gravity 1 1 instance 11 exposed
Issued
Nov 1, 2012
Abate by
Nov 13, 2012
Penalty
Initial $2,295 · Current $2,295
29 CFR 1910.37(b)(1): Each exit route was not adequately lighted so that an employee with normal vision can see along the exit route.    a) Warehouse North West Exit door - On or about 31 May, 2012 - The emergency exit lighting was inoperable at the exit door and in the event of an emergency employees would not be able to find their way to the door. Employees were exposed to a fire hazard.
Recent events (1)
  • — Z (S) $2295

1910.37 B06

Serious Gravity 5 1 instance 11 exposed
Issued
Nov 1, 2012
Abate by
Nov 13, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color:    a) Warehouse North West Exit door - On or about 31 May, 2012 - The exit sign above the fire exit on the NorthWest wall of the warehouse was inoperable and in the event of a fire or emergency employees would not be able to identify the door as an emergency exit. Employees were exposed to a fire hazard.
Recent events (1)
  • — Z (S) $0

1910.110 F02 I

Serious Gravity 1 3 instances 2 exposed
Issued
Nov 1, 2012
Penalty
Initial $2,295 · Current $2,295
29 CFR 1910.110(f)(2)(i): Containers in storage were not located so as to minimize exposure to excessive temperature rise, physical damage, or tampering by unauthorized persons.    a) Warehouse loading dock - On or about 31 May, 2012 - LP gas cylinders were stored in the warehouse adjacent to the loading dock opening. Containers were not secured to prevent physical damage, excessive temperature rise or tampering by unauthorized persons.
Recent events (1)
  • — Z (S) $2295

1910.157 E03

Serious Gravity 1 40 instances 11 exposed
Issued
Nov 1, 2012
Abate by
Nov 13, 2012
Penalty
Initial $2,295 · Current $2,295
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:  Note:  Applies to any extinguishers provided in the workplace.  Maintenance check includes an internal examination, except extinguishers with stored pressure.    a) Warehouse thoughout - On or about 31 May, 2012 - Fire extinguishers located throughout the warehouse had not been annually inspected since September 2007.
Recent events (1)
  • — Z (S) $2295

1910.157 G01

Serious Gravity 5 1 instance 11 exposed
Issued
Nov 1, 2012
Abate by
Nov 13, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting:  Note:  Applies where all employees are expected to fight fires.    a) Building - On or about 31 May, 2012 - Employees were not trained in the use of portable fire extinguishers.    Abatement Note: The employer must either correct the alleged violation item(s) or implement a Fire Safety Policy, as outlined in 29 CFR 1910.38(a) and (b), which includes the evacuation requirements in 29 CFR 1910.157(b).    Pursuant to 29 CFR 1903.19(d), the employer must provide certification to OSHA that this violation has been abated with 10 calendar days of the "Date by which Violation Must be Abated".
Recent events (1)
  • — Z (S) $0

1910.141 A05

Other-than-serious 1 instance 11 exposed
Issued
Nov 1, 2012
Abate by
Nov 16, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.141(a)(5): A continuing and effective extermination program was not instituted where rodents, insects, or other vermin were detected:    a) Warehouse Employee Breakroom - On or about 31 May, 2012 - Employees using the breakroom to eat lunch were exposed to rodent excrement on the surfaces of the tables.
Recent events (1)
  • — Z (O) $0

1910.178 L06

Other-than-serious 2 instances 2 exposed
Issued
Nov 1, 2012
Abate by
Nov 16, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6): The employer did not certify that each operator was trained and certified in the operation of powered industrial trucks.    a) Warehouse - On or about 31 May, 2012 - For operators of the Caterpillar F-30 forklift.