Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: R AND R FRASIER BUILDERS LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of R AND R FRASIER BUILDERS LLC in 135 STEVERS MILLS ROAD, BROADALBIN, NY 12025 (NAICS 238160). OSHA activity number 334529732.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch R and R Frasier Builders LLC for free Get an email when a new federal OSHA severe-injury report for R and R Frasier Builders LLC is published. One employer, no account, unsubscribe in one click.
Site address
135 STEVERS MILLS ROAD
City
BROADALBIN
State
NY
ZIP
12025
Mailing
198 PRIDDLE POINT ROAD, GLOVERSVILLE, NY 12078
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
Private (A)

6 citations on file for this inspection.

1926.451 G01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 13, 2012
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.451(g)(1)(i): Each employee on a ladder jack scaffold shall be protected by a personal fall arrest system.    a) Building site - On or about 1 June, 2012 - Employees were installing exterior sheathing on the front of the building while working on ladder jack scaffolding without any fall protection. Employee was exposed to a fall hazard of 20 feet.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2800

1926.451 E01

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 13, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used.     a) Building front - On or about 1 June, 2012 - Employees were installing exterior sheathing on a home while working off a ladder jack scaffold without a seperate access ladder to the top of the scaffold. Employees were exposed to a fall hazard of 20 feet.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.501 B13

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 13, 2012
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor  did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502.    a) Building, First Floor - On or about 1 June, 2012 - Employees were installing interior walls on the first floor and were exposed to a fall hazard by an unguarded floor opening. Employees were exposed to a fall hazard of 7 feet.
Recent events (2)
  • · I (S) $800
  • · Z (S) $1600

1926.404 B01 II

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 13, 2012
Abate by
Aug 22, 2012
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection.    a) Building first floor - On or about 1 June, 2012 - Employees were using power tools with damaged cords, that were supplied power without ground fault circuit interrupter protection. Employees were exposed to an electrocution hazard.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2000

1926.416 E01

Serious Gravity 10 2 instances 4 exposed
Issued
Aug 13, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:    a) Building first floor - On or about 1 June, 2012 - Employees were using a power saw to cut lumber that had a worn electric cord. Employees were exposed to an electrocution hazard.     b) Building first floor - On or about 1 June, 2012 - Employees were using an extension cord to supply power to a power saw that had a worn electrical cord at the point of the plug. Employees were exposed to an electrocution hazard.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.405 B02

Serious Gravity 1 1 instance 4 exposed
Issued
Aug 13, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy:    a) Building first floor - On or about 1 June, 2012 - Electrical outlets that employees were using were energized and did not have cover plates on them. Employees were exposed to an electric shock hazard.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0