BURLINGTON, WI —
OSHA Inspection: HIGH QUALITY CONTRACTING INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HIGH QUALITY CONTRACTING INC. in 432 S. KANE ST., BURLINGTON, WI 53105 (NAICS 238130). OSHA activity number 334538139.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HIGH QUALITY CONTRACTING INC.
- Site address
- 432 S. KANE ST.
- City
- BURLINGTON
- State
- WI
- ZIP
- 53105
- Mailing
- 7542 RIVERVIEW RD., FRANKLIN, WI 53132
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 5
- Ownership type
- A
Citations
1 citation on file for this inspection.
1926.451 F06
- Issued
- Jun 18, 2012
- Abate by
- Jun 19, 2012
- Penalty
- Initial $2,800 · Current $1,500 Reduced
General-duty citation text
29 CFR 1926.451(f)(6): The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines than as follows: *Insulated Lines _____________________________________________________________________ Voltage Minimum distance Alternatives ____________________ ________________________ _______________________ Less than 300 volts. 3 feet (0.9 m) 300 volts to 50 kv. 10 feet (3.1 m) More than 50 kv..... 10 feet (3.1 m) plus 2 times the length 0.4 inches (1.0 cm) of the line for each 1 kv over insulator, but never 50 kv. less than 10 feet (3.1 m). ____________________ ________________________ _______________________ *Uninsulated lines _____________________________________________________________________ Voltage Minimum distance Alternatives ____________________ ________________________ _______________________ Less than 50 kv..... 10 feet (3.1 m). More than 50 kv..... 10 feet (3.1 m) plus 2 times the length of 0.4 inches (1.0 cm) the line insulator, for each 1 kv over but never less than 50 kv. 10 feet (3.1 m). ____________________ ________________________ _______________________ Exception to paragraph (f)(6): Scaffolds and materials may be closer to power lines than specified above where such clearance is necessary for performance of work, and only after the utility company, or electrical system operator, has been notified of the need to work closer and the utility company, or electrical system operator, has deenergized the lines, relocated the lines, or installed protective coverings to prevent accidental contact with the lines. (a) Employees were conducting gutter and fascia work from a ladder jack scaffold that was within 3 feet of an uninsulated energized power line. (less than 50kv)
Recent events (2)
- — I (S) $1500
- — Z (S) $2800
More inspections at High Quality Contracting INC.
View High Quality Contracting INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334538139.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.