Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: OXFORD BOATYARD

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of OXFORD BOATYARD in 402 EAST STRAND, OXFORD, MD 21654 (NAICS 713930). OSHA activity number 334569332.

Watch Oxford Boatyard — free Get an email when a new federal OSHA severe-injury report for Oxford Boatyard is published. One employer, no account, unsubscribe in one click.
Establishment
OXFORD BOATYARD
Site address
402 EAST STRAND
City
OXFORD
State
MD
ZIP
21654
Mailing
402 EAST STRAND, OXFORD, MD 21654
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
713930
Employees
18
Ownership type
A

11 citations on file for this inspection.

1910.107 B05 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1700.00 · Current $1100.00 Reduced
29 CFR 1910.107(b)(5)(i): The spraying operation except electrostatic spraying operations was not designed, installed and maintained so that the average air velocity over the open face of the booth (or booth cross section during spraying operations) exceeded 100 linear feet per minute. Visible gauges or audible alarn or pressure activated devices were not installed to indicate or insure that the required air velocity was maintained:    a) Spray Shed - A painter was spray painting in a booth and had no indication of the amount of air flow traveling within the booth, on or about 06/05/2012.     ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1100
  • — Z (S) $1700

1910.107 B05 IV

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.107(b)(5)(iv):  Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers:    a) Spray Shed - Spray painting operations were taking place, and no automatic sprinkler system had been provided, on or about 06/05/2012.       ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 B09

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.107(b)(9):  A clear space of not less than 3 feet on all sides was not kept free from storage or combustible construction:    a) Spray Shed - Storage cabinets and tables were stored up against the interior wall, on or about 06/05/2012.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 C05

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1700.00 · Current $1100.00 Reduced
29 CFR 1910.107(c)(5):  Electrical equipment that was not specifically approved for locations containing both deposits of readily ignitable residue and explosive vapors were located in a spray area:    a) Spray Shed - Electrical outlets, florescent light fixtures, ceiling fan and exhaust fans were located within the spray area where flammable paints and solvents were sprayed, on or about 06/05/2012.    ABATEMENT CERTFICATION REQUIRED
Recent events (2)
  • — I (S) $1100
  • — Z (S) $1700

1910.107 G07

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.107(g)(7):  "No Smoking" signs in large letters on contrasting color background were not conspicuously posted at all spraying areas and paint storage rooms:    a) Spray Shed - No smoking signs were not posted at the spray shed, on or about 06/05/2012.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1360.00 · Current $816.00 Reduced
29 CFR 1910.134(c)(1):  A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:    a) Paint Shed -  Painters engaged in spray painting fiberglass surfaces on boats, were required to wear either 3M full face or half face respirators and a respiratory protection program had not been developed, on or about 06/05/2012.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $816
  • — Z (S) $1360

1910.134 E01

Serious Gravity 5 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(e)(1):  The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:    a) Paint Shed - Painters were using 3M full and half face duel cartridge respirators while applying AWL Grip Polyester Urethane Top Coat Base with a spray gun, and a medical evaluation was not provided, on or about 06/05/2012.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F01

Serious 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(f)(1):  The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT):    a) Painters were using 3M full and half face duel cartridge respirators while applying AWL Grip Polyester Urethane Top Coat Base with a spray gun, and fit testing was not provided, on or about 06/05/2012.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.151 C

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1360.00 · Current $816.00 Reduced
29 CFR 1910.151(c):  Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    a) Battery Shed - A portable eye wash station was empty of water, on or about 06/05/2012.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $816
  • — Z (S) $1360

1910.212 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1360.00 · Current $816.00 Reduced
29 CFR 1910.212(a)(1):  One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a) Machine Shop - A mechanic was using a Rockwell model lathe and a chuck guard was not provided, on or about 06/05/2012.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $816
  • — Z (S) $1360

1910.303 G02 I

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1020.00 · Current $612.00 Reduced
29 CFR 1910.303(g)(2)(i):  Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    a) Spar Shed - Electrical service panel was missing a circuit breaker insert and live electric parts were exposed, on or about 06/05/2012.     ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $612
  • — Z (S) $1020

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334569332.