CLEVELAND, OH —
OSHA Inspection: PARK OHIO PRODUCTS INC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of PARK OHIO PRODUCTS INC in 7000 DENISON AVE, CLEVELAND, OH 44102 (NAICS 326299). OSHA activity number 334574936.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PARK OHIO PRODUCTS INC
- Site address
- 7000 DENISON AVE
- City
- CLEVELAND
- State
- OH
- ZIP
- 44102
- Mailing
- 7000 DENISON AVE, CLEVELAND, OH 44102
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326299
- Employees
- 200
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 II B
- Issued
- Jul 31, 2012
- Abate by
- Aug 5, 2012
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: The lockout procedure did not address the blocking or securing of the core bar which can fall during unjamming the machine.
Recent events (2)
- — I (S) $7000
- — Z (S) $7000
1910.147 D04 I
- Issued
- Jul 31, 2012
- Abate by
- Aug 5, 2012
- Penalty
- Initial $7,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: On March 28, 2012, employees unjamming the T2-2 press did not apply lockout devices.
Recent events (2)
- — I (S) $0
- — Z (S) $7000
1910.304 G05
- Issued
- Jul 31, 2012
- Abate by
- Jul 31, 2012
- Penalty
- Initial $2,805 · Current $2,805
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent and continuous: A man cooling fan was not grounded because the ground prong was broken off the electrical plug.
Recent events (2)
- — I (S) $2805
- — Z (S) $2805
More inspections at Park Ohio Products INC
View Park Ohio Products INC's full OSHA safety record →
More inspections in this industry (NAICS 326299)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334574936.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.