OSHA Inspection: STRUCTURAL METALS OF KANSAS CITY, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STRUCTURAL METALS OF KANSAS CITY, INC in 1911 TELEVISION PLACE, KANSAS CITY, MO 64126 (NAICS 332312). OSHA activity number 334575735.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Structural Metals of Kansas City, INC for free Get an email when a new federal OSHA severe-injury report for Structural Metals of Kansas City, INC is published. One employer, no account, unsubscribe in one click.
Site address
1911 TELEVISION PLACE
City
KANSAS CITY
State
MO
ZIP
64126
Mailing
1911 TELEVISION PLACE, KANSAS CITY, MO 64126
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
12
Ownership type
Private (A)

4 citations on file for this inspection.

1910.101 A

Other-than-serious 2 instances 1 exposed
Issued
Jul 26, 2012
Penalty
Initial $1,360 · Current $680 Reduced
29 CFR 1910.101(a): The employer did not determine that compressed gas cylinders under his control were in a safe condition to the extent that this could be determined by visual inspection:  (a)  On June 06, 2012, The employer did not ensure that the welding gas cylinder located in the welding area of the facility was in an safe condition, in that the glass covers for the gauges were missing allowing dirt and debris to accumulate to a level that made the pressure gauge dial totally unreadable.  Employees were exposed to serious struck by injuries in the event of an accident from an incorrect determination of the pressure readings.           Abatement certification for this violation is not required.
Recent events (2)
  • · I (O) $680
  • · Z (S) $1360

1910.178 L04 III

Other-than-serious 3 instances 11 exposed
Issued
Jul 26, 2012
Abate by
Aug 16, 2012
Penalty
Initial $1,360 · Current $680 Reduced
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:  (a)  On June 12, 2012, at the facility located at 1911 Television Pl,  Kansas City, MO.,  The employer had not ensured that all authorized powered industrial truck operators were currently certified, in that their last three year performance evaluation was performed on November 07, 2007.         Abatement certification is required for this item; use the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET for this purpose.
Recent events (2)
  • · I (O) $680
  • · Z (S) $1360

1910.212 A05

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Jul 26, 2012
Penalty
Initial $1,360 · Current $0 Reduced
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch:  (a)  On June 06, 2012, in the main fabrication area of the facility, the employer did not ensure that the Portable Vornado Fan used by an employee was equipped with fan blade guard openings that were one half inch or less.          Abatement certification for this violation is not required.
Recent events (2)
  • · I (S) $0
  • · Z (S) $1360

1910.334 A02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 26, 2012
Penalty
Initial $1,020 · Current $710 Reduced
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment was not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  (a)  On June 6, 2012, in the main fabrication area of the facility, the Portable Vornado Fan had not been visually inspected for external defects, in that the power cord outer jacket and insulation was badly damaged and defective.          Abatement certification for this violation is not required.
Recent events (2)
  • · I (S) $710
  • · Z (S) $1020

View Structural Metals of Kansas City, INC's full OSHA safety record →