KANSAS CITY, MO —
OSHA Inspection: STRUCTURAL METALS OF KANSAS CITY, INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of STRUCTURAL METALS OF KANSAS CITY, INC in 1911 TELEVISION PLACE, KANSAS CITY, MO 64126 (NAICS 332312). OSHA activity number 334575735.
Where did this inspection happen?
- Establishment
- STRUCTURAL METALS OF KANSAS CITY, INC
- Site address
- 1911 TELEVISION PLACE
- City
- KANSAS CITY
- State
- MO
- ZIP
- 64126
- Mailing
- 1911 TELEVISION PLACE, KANSAS CITY, MO 64126
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 12
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.101 A
- Issued
- Penalty
- Initial $1360.00 · Current $680.00 Reduced
General-duty citation text
29 CFR 1910.101(a): The employer did not determine that compressed gas cylinders under his control were in a safe condition to the extent that this could be determined by visual inspection: (a) On June 06, 2012, The employer did not ensure that the welding gas cylinder located in the welding area of the facility was in an safe condition, in that the glass covers for the gauges were missing allowing dirt and debris to accumulate to a level that made the pressure gauge dial totally unreadable. Employees were exposed to serious struck by injuries in the event of an accident from an incorrect determination of the pressure readings. Abatement certification for this violation is not required.
Recent events (2)
- — I (O) $680
- — Z (S) $1360
1910.178 L04 III
- Issued
- Abate by
- Penalty
- Initial $1360.00 · Current $680.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: (a) On June 12, 2012, at the facility located at 1911 Television Pl, Kansas City, MO., The employer had not ensured that all authorized powered industrial truck operators were currently certified, in that their last three year performance evaluation was performed on November 07, 2007. Abatement certification is required for this item; use the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET for this purpose.
Recent events (2)
- — I (O) $680
- — Z (S) $1360
1910.212 A05
- Issued
- Penalty
- Initial $1360.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch: (a) On June 06, 2012, in the main fabrication area of the facility, the employer did not ensure that the Portable Vornado Fan used by an employee was equipped with fan blade guard openings that were one half inch or less. Abatement certification for this violation is not required.
Recent events (2)
- — I (S) $0
- — Z (S) $1360
1910.334 A02 I
- Issued
- Penalty
- Initial $1020.00 · Current $710.00 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment was not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): (a) On June 6, 2012, in the main fabrication area of the facility, the Portable Vornado Fan had not been visually inspected for external defects, in that the power cord outer jacket and insulation was badly damaged and defective. Abatement certification for this violation is not required.
Recent events (2)
- — I (S) $710
- — Z (S) $1020
More inspections at STRUCTURAL METALS OF KANSAS CITY, INC
KANSAS CITY, MO—2014-11-13 00:00:00
STRUCTURAL METALS OF KANSAS CITY, INC
KANSAS CITY, MO—2012-02-24 00:00:00
STRUCTURAL METALS OF KANSAS CITY, INC.
KANSAS CITY, MO—2009-07-16 00:00:00
STRUCTURAL METALS OF KANSAS CITY, INC.
View STRUCTURAL METALS OF KANSAS CITY, INC's full OSHA safety record →
More inspections in this industry (NAICS 332312)
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
CAMDEN, NJ—2026-07-08
CENTRAL METALS, INC.
SACRAMENTO, CA—2026-07-07
MARTIN'S STEEL WORKS, INC
LOUISVILLE, KY—2026-07-01
69275 - NORTH AMERICAN INDUSTRIAL SUPPLY INC
More inspections in MO
KANSAS CITY, MO—2026-07-09
NIAGARA BOTTLING
MONETT, MO—2026-07-09
MONETT METALS INC.
PARKVILLE, MO—2026-07-08
SKY-TECH ROOFING, LLC.
SPRINGFIELD, MO—2026-07-07
D & C CONSTRUCTION, LLC.
JOPLIN, MO—2026-07-07
SERVICE RECYCLING - NORTH PLANT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334575735.