Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MARCELO CARVALHO

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MARCELO CARVALHO in 13310 MELROSE LN, OVERLAND PARK, KS 66221 (NAICS 238170). OSHA activity number 334579737.

Watch Marcelo Carvalho — free Get an email when a new federal OSHA severe-injury report for Marcelo Carvalho is published. One employer, no account, unsubscribe in one click.
Establishment
MARCELO CARVALHO
Site address
13310 MELROSE LN
City
OVERLAND PARK
State
KS
ZIP
66221
Mailing
1590 WEST MULBERRY ST, OLATHE, KS 66061
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
12
Ownership type
A

9 citations on file for this inspection.

1926.20 B01

Deleted Serious Gravity 5 12 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $0.00 Reduced
29 CFR 1926.20(b)(1): It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part.  The employer has not developed the required programs to ensure that employees are not exposed to workplace hazards to include but not limited to electrical hazards and fall hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

1926.404 F06

Deleted Serious Gravity 1 12 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $0.00 Reduced
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.  At the time of the inspection the electrical extension cords providing power to two air compressors did not have a ground pin installed. Employees were exposed to shock hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1200

1926.405 A02 II I

Deleted Serious Gravity 1 12 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $0.00 Reduced
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables shall be protected from damage. Sharp corners and projections shall be avoided. Flexible cords and cables may pass through doorways or other pinch points, if protection is provided to avoid damage.  At the time of the inspection a yellow AWG 12/3 extension cord was run across the road way were it was being runover by construction equipment. Employees were exposed to a shock hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1200

1926.416 E01

Deleted Serious Gravity 1 12 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $0.00 Reduced
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables shall not be used.  The two yellow AWG 12 extension cords being used to provide power to the air compressors being used for siding installation from metal scaffolds had several areas where the outer insulation was broken/worn away. Employees were exposed to a shock hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1200

1926.451 F03

Deleted Serious Gravity 5 12 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $0.00 Reduced
29 CFR 1926.451(f)(3): Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.  At the time of the inspection the scaffolds being utilized had not been inspected by a competent person to ensure the scaffolds in use were properly errected. Employees were exposed to falls of approximately fifteen (15) feet to the compacted ground below.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

1926.451 G01 VII

Deleted Serious Gravity 5 12 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $0.00 Reduced
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.  At the time of the inspection employees were observed to be performing siding operations from jack-up type scaffolds that did not have fall protection installed on the ends and only had an upper railing on the remainder of the scaffold to act as fall protection. Employees were exposed to a fall hazard in excess of fifteen 915) feet to the ground below.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

1926.454 A

Deleted Serious Gravity 5 12 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $0.00 Reduced
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards.  At the time of the inspection employees were observed to be performing siding operations on juck-up scaffolds and these employees had not been trained to recognize and abate the hazards. Employees were exposed to fall hazard of approximately fifteen (15) feet to the ground.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

1926.1053 B01

Deleted Serious Gravity 5 12 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $0.00 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladders length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  At the time of the inspection the ladder being used to access the roof that was used to access the scaffold extended only one (1) rung above the eave of the roof and was not attached to the building. Employees were exposed to a fall hazard of approximately eight (8) feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1600

1926.1053 B04

Deleted Serious Gravity 5 3 instances 12 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $0.00 Reduced
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:  1. An aluminum extension ladder was being used as the vertical support for a pump-jack-up. Employees were exposed to a fall hazard of approximately fifteen (15) feet.  2. An aluminum extension ladder was being used as a work platform/guard rail on the pump-jack scaffold. Employees were exposed to a fall hazard of approximately fifteen (15) feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334579737.