CONTOOCOOK, NH —
OSHA Inspection: HMC CORPORATION
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of HMC CORPORATION in 284 MAPLE STREET, CONTOOCOOK, NH 03229 (NAICS 333210). OSHA activity number 334587540.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HMC CORPORATION
- Site address
- 284 MAPLE STREET
- City
- CONTOOCOOK
- State
- NH
- ZIP
- 03229
- Mailing
- 284 MAPLE STREET, CONTOOCOOK, NH 03229
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333210
- Employees
- 19
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.107 G05
- Issued
- Sep 25, 2012
- Abate by
- Oct 2, 2012
- Penalty
- Initial $1,700 · Current $850 Reduced
General-duty citation text
29 CFR 1910.107(g)(5): The use of solvents for cleaning operations was not restricted to those having flashpoints not less than 100 F.: a. Spray room - Acetone was being used to clean spray nozzles and auxillary equipment. Acetone has lower flashpoint than paint and thinner in use.
Recent events (2)
- — I (S) $850
- — Z (S) $1700
1910.134 D03 III B 2
- Issued
- Sep 25, 2012
- Abate by
- Nov 7, 2012
- Penalty
- Initial $1,020 · Current $680 Reduced
General-duty citation text
29 CFR 1910.134(d)(3)(iii)(B)(2): The employer did not implement a change schedule for respirators not equipped with an End of Service Life Indicator that would ensure cartridges were changed before the end of their service life: (a) Spray Room - Painter, required to use a respirator to protect from vapors such as xylene and acetone, had not been provided with a change schedule. Note: The employer may provide an air-purifying respirator provided the respirator is equipped with end-of-service-life indicators or a change schedule has been developed. Otherwise, the employer must provide an atmosphere-supplying respirator.
Recent events (2)
- — I (S) $680
- — Z (S) $1020
1910.134 E01
- Issued
- Sep 25, 2012
- Abate by
- Oct 2, 2012
- Penalty
- Initial $1,360 · Current $0 Reduced
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a)Spray Room - Painter, required to use a respirator did not have a medical evaluation to determine his ability to use a respirator. Note: The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.
Recent events (2)
- — I (S) $0
- — Z (S) $1360
1910.147 C06 I
- Issued
- Sep 25, 2012
- Abate by
- Nov 6, 2012
- Penalty
- Initial $1,700 · Current $850 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a. Establishment - Employer had established a lockout program and developed and implemented lockout procedures for equipment such as Marvel saw, but was not conducting periodic inspections at least annually to ensure that procedures were being followed.
Recent events (2)
- — I (S) $850
- — Z (S) $1700
1910.335 A01 I
- Issued
- Sep 25, 2012
- Abate by
- Dec 3, 2012
- Penalty
- Initial $1,700 · Current $850 Reduced
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed: (a) Test area - Employee building and testing control panels for equipment was not provided with electrical protective gloves needed for working on live parts.
Recent events (2)
- — I (S) $850
- — Z (S) $1700
1910.1025 D02
- Issued
- Sep 25, 2012
- Penalty
- Initial $1,700 · Current $850 Reduced
1591
General-duty citation text
29 CFR 1910.1025(d)(2): An initial determination was not made to determine if any employee may be exposed to lead at or above the action level: (a) Paint room - On or about 7/11/12, an employee spray painting machine parts was exposed to airborne lead at an 8-hour time weighted average (TWA) of 26 micrograms/ cubic meter. Exposure was based on one sample taken over 42 minutes at 297 micrograms/ cubic meter. Zero exposure was assumed for the 438 minutes not sampled. Lead exposures may cause damage to blood-forming, nervous, urinary, and reproductive systems.
Recent events (2)
- — I (S) $850
- — Z (S) $1700
1910.1025 D04 I
- Issued
- Sep 25, 2012
- Penalty
- Initial $0 · Current $0
1591
General-duty citation text
29 CFR 1910.1025(d)(4)(i): Where the initial determination showed the possibility of employee exposure at or above the action level, representative monitoring was not conducted for each employee in the workplace who was exposed to lead: (a) Paint room - On or about 7/11/12, an employee spray painting machine parts was exposed to airborne lead at an 8-hour time weighted average (TWA) of 26 micrograms/ cubic meter. Exposure was based on one sample taken over 42 minutes at 297 micrograms/ cubic meter. Zero exposure was assumed for the 438 minutes not sampled. Lead exposures may cause damage to blood-forming, nervous, urinary, and reproductive systems.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1025 L01 I
- Issued
- Sep 25, 2012
- Abate by
- Oct 2, 2012
- Penalty
- Initial $1,360 · Current $0 Reduced
1591
General-duty citation text
29 CFR 1910.1025(l)(1)(i): Employee(s) working in an area where there is potential exposure to airborne lead at any level were not informed of the content of Appendices A and B of 29 CFR 1910.1025: (a) Paint room - On or about 7/11/12, an employee spray painting machine parts was exposed to airborne lead at an 8-hour time weighted average (TWA) of 26 micrograms/ cubic meter. Exposure was based on one sample taken over 42 minutes at 297 micrograms/ cubic meter. Zero exposure was assumed for the 438 minutes not sampled. Lead exposures may cause damage to blood-forming, nervous, urinary, and reproductive systems. Employees were not informed of the content of Appendices A and B of 29 CFR 1910.1025.
Recent events (2)
- — I (S) $0
- — Z (S) $1360
More inspections at HMC Corporation
View HMC Corporation's full OSHA safety record →
More inspections in this industry (NAICS 333210)
More inspections in NH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334587540.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.