Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: CENTURY CONCRETE PRODUCTS

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of CENTURY CONCRETE PRODUCTS in 296 FIKE HOLLOW ROAD, MEYERSDALE, PA 15552 (NAICS 327390). OSHA activity number 334592540.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Century Concrete Products for free Get an email when a new federal OSHA severe-injury report for Century Concrete Products is published. One employer, no account, unsubscribe in one click.
Site address
296 FIKE HOLLOW ROAD
City
MEYERSDALE
State
PA
ZIP
15552
Mailing
296 FIKE HOLLOW ROAD, MEYERSDALE, PA 15552
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327390
Employees
2
Ownership type
A

5 citations on file for this inspection.

1910.1200 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 16, 2012
Abate by
Sep 10, 2012
Penalty
Initial $1,200 · Current $600 Reduced
29 CFR 1910.1200(e)(1):  The employer did not develop, implement, and maintain at each workplace a written hazard communication program which at least described how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met:    a)  At the facility - A written hazard communication program had not been developed, implemented and maintained.  Employees use hazardous chemicals such as, but not limited to, Portland Cement (a corrosive) and Duogard Form Release Agent.
Recent events (2)
  • · I (S) $600
  • · Z (S) $1200

1910.1200 G01

Serious Gravity 1 2 instances 1 exposed
Issued
Aug 16, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet in the workplace for each hazardous chemical which they use:    a)  The employer did not have mateiral safety data sheets for Portland Cement, a corrosive, and Duogard Form Release Agent.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.132 D02

Other-than-serious 1 instance 1 exposed
Issued
Aug 16, 2012
Abate by
Aug 26, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment had been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment:    a) In the facility, on or about June 1, 2012 - The employer did not certify a written hazard assessment performed in the facility.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.138 B

Other-than-serious 1 instance 1 exposed
Issued
Aug 16, 2012
Abate by
Aug 26, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.138(b): Employers did not base the selection of the appropriate hand protection on an evaluation of the performance characteristics of the hand protection relative to the task(s) to be performed, conditions present, duration of use, and the hazards and potential hazards identified:    a) In the facility, on or about June 1, 2012 -  Employees used cotton gloves while handling Portland cement and form oil.  The cotton gloves had to be changed frequently due to saturation with cement.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.304 G05

Other-than-serious 1 instance 1 exposed
Issued
Aug 16, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.304(g)(5):  The path to ground from circuits, equipment, and enclosures were not permanent, continuous, and effective:    a)  At the facility - The industrial fan was not grounded as its ground prong was damaged and cracked.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334592540.