Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: CONOVER LUMBER COMPANY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CONOVER LUMBER COMPANY, INC. in 7960 ALCONY-CONOVER RD., CONOVER, OH 45317 (NAICS 321920). OSHA activity number 334610938.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Conover Lumber Company, INC. for free Get an email when a new federal OSHA severe-injury report for Conover Lumber Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
7960 ALCONY-CONOVER RD.
City
CONOVER
State
OH
ZIP
45317
Mailing
7960 ALCONY-CONOVER RD., CONOVER, OH 45317
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
23
Ownership type
Private (A)

7 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 6, 2012
Abate by
Aug 17, 2012
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1910.212(a)(1):     One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    -While operating the Newman KM-16 multi-head cross-cut saw, employees were exposed to nip points on the discharge conveyor belt.
Recent events (2)
  • · I (S) $1120
  • · Z (S) $1600

1910.213 F01

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 6, 2012
Abate by
Aug 17, 2012
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1910.213(f)(1):     Feed rolls and saws on self-feed circular saw(s) were not protected by a hood or guard to prevent the hands of the operator from coming in contact with the in-running rolls:    -The Whitney self-feed table saw was not adequately guarded in that employees were exposed to the blade on the fence side of the feeder.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2000

1910.213 F02

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 6, 2012
Abate by
Aug 17, 2012
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1910.213(f)(2):     Self-feed circular ripsaw(s) were not provided with sectional non-kickback fingers for the full width of the feed rolls:    -The Whitney self-feed circular saw was not equipped with anti-kickback fingers the full length of the feed rollers.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2000

1910.213 H01

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 6, 2012
Penalty
Initial $1,700 · Current $1,190 Reduced
29 CFR 1910.213(h)(1):     The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the material:    -The guards for the lower exposed portion of the blade on the Rockwell/Delta radial arm saw were taped up, providing no protection during operation.
Recent events (2)
  • · I (S) $1190
  • · Z (S) $1700

1910.213 R04

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 6, 2012
Abate by
Aug 17, 2012
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1910.213(r)(4):     Suitable guard(s) were not provided to reduce to a minimum the hazard at the point of operation of a upstroke cross-cut saw:      -Employees were exposed to amputation hazards due to inadequate guarding on the Whirlwind up-stroke cross-cut saw.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2000

1910.304 G05

Serious Gravity 1 1 instance 4 exposed
Issued
Jul 6, 2012
Abate by
Aug 3, 2012
Penalty
Initial $1,200 · Current $840 Reduced
29 CFR 1910.304(g)(5):     The paths to ground from circuits, equipment, and enclosures were not permanent, continuous, and effective:    The Sanyo brand refrigerator was plugged into the receptacle but was missing the grounding pin in the plug, breaking the continuous path to ground.
Recent events (2)
  • · I (S) $840
  • · Z (S) $1200

1910.147 C04 I

Other-than-serious 1 instance 1 exposed
Issued
Jul 6, 2012
Abate by
Aug 17, 2012
Penalty
Initial $400 · Current $280 Reduced
29 CFR 1910.147(c)(4)(i):     Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:      -Procedures were not developed for equipment with multiple energy sources such as, but not limited to, the Rayco Pallet Maker and the Whirlwind crosscut saw.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET)
Recent events (2)
  • · I (O) $280
  • · Z (O) $400

View Conover Lumber Company, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 334610938.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.